Sensors 2001, 1(3), 91-101; doi:10.3390/s10300091
Article

An Optical Biosensor for Monitoring Antigen Recognition Based on Surface Plasmon Resonance Using Avidin-Biotin System

1 Department of Chemistry, Jilin University, Changchun, Jilin 130023, P. R. China 2 Key Laboratory of Molecular Enzymology and Engineering of Ministry of Education, Jilin University, Changchun, Jilin 130023, P. R. China
* Author to whom correspondence should be addressed.
Received: 21 July 2001; in revised form: 29 July 2001 / Accepted: 7 August 2001 / Published: 12 August 2001
PDF Full-text Download PDF Full-Text [74 KB, uploaded 1 October 2008 09:01 CET]
Abstract: A novel optical biosensor based on simultaneous multiwave length detection surface plasmon resonance (SPR) has been developed for immunosensing. The sensor is designed on the basis of fixing angle of incidence and measuring the reflected intensities of light in the wavelength range of 400–800 nm. The SPR spectra are shown in terms of reflected light intensity verus wavelength of incident light. The intensity of the reflected light is the minimum at the resonant wavelength. The biorecognition surface, formed on a chemically modified gold layer, consists of avidin that is specifically bound with biotin. These sensing membranes were self-assembled on gold layer. The processes of sensing monolayer formation were studied in real time through observing the change of resonant wavelength. The modified surface was used as a model immunosensor and to detect successfully the human factor B (Bf). The Bf was determined in the concentration range of 0.5~100 μg/mL. Under optimum experimental conditions, the sensor has a good repeatability, reversibility and selectivity.
Keywords: Surface plasmon resonance; Biosensor; Avidin; Biotin

Article Statistics

Click here to load and display the download statistics.

Cite This Article

MDPI and ACS Style

Mu, Y.; Zhang, H.; Zhao, X.; Song, D.; Wang, Z.; Sun, J.; Li, M.; Jin, Q. An Optical Biosensor for Monitoring Antigen Recognition Based on Surface Plasmon Resonance Using Avidin-Biotin System. Sensors 2001, 1, 91-101.

AMA Style

Mu Y., Zhang H., Zhao X., Song D., Wang Z., Sun J., Li M., Jin Q. An Optical Biosensor for Monitoring Antigen Recognition Based on Surface Plasmon Resonance Using Avidin-Biotin System. Sensors. 2001; 1(3):91-101.

Chicago/Turabian Style

Mu, Ying; Zhang, Hanqi; Zhao, Xiaojun; Song, Daqian; Wang, Zhen; Sun, Jing; Li, Minjing; Jin, Qinhan. 2001. "An Optical Biosensor for Monitoring Antigen Recognition Based on Surface Plasmon Resonance Using Avidin-Biotin System." Sensors 1, no. 3: 91-101.

Sensors EISSN 1424-8220 Published by MDPI Publishing, Basel, Switzerland RSS E-Mail Table of Contents Alert