Next Article in Journal
Mangiferin Facilitates Islet Regeneration and β-Cell Proliferation through Upregulation of Cell Cycle and β-Cell Regeneration Regulators
Next Article in Special Issue
Antibacterial Effect of Dental Adhesive Containing Dimethylaminododecyl Methacrylate on the Development of Streptococcus mutans Biofilm
Previous Article in Journal
Transition from Cyclosporine-Induced Renal Dysfunction to Nephrotoxicity in an in Vivo Rat Model
Previous Article in Special Issue
Editorial of the Special Issue Antimicrobial Polymers
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Effect of a Novel Quaternary Ammonium Methacrylate Polymer (QAMP) on Adhesion and Antibacterial Properties of Dental Adhesives

1
Postgraduate Program in Dentistry, Department of Dentistry, State University of Ponta Grossa, Paraná 84030-900, Brazil
2
Laboratory of Pharmaceutical Products, Postgraduate Program in Pharmaceutical Sciences, Department of Pharmaceutical Sciences, State University of Ponta Grossa, Paraná 84030-900, Brazil
3
Multi-user Laboratory, State University of Ponta Grossa, Paraná 84030-900, Brazil
4
Laboratory of Clinical Microbiology, Department of Clinical and Toxicological Analysis, State University of Ponta Grossa, Paraná, 84030-900, Brazil
*
Author to whom correspondence should be addressed.
Int. J. Mol. Sci. 2014, 15(5), 8998-9015; https://doi.org/10.3390/ijms15058998
Submission received: 3 March 2014 / Revised: 14 April 2014 / Accepted: 16 April 2014 / Published: 20 May 2014
(This article belongs to the Special Issue Antimicrobial Polymers)

Abstract

:
This study investigated the resin–dentin bond strength (μTBS), degree of conversion (DC), and antibacterial potential of an innovative adhesive system containing a quaternary ammonium methacrylate polymer (QAMP) using in situ and in vitro assays. Forty-two human third molars were flattened until the dentin was exposed and were randomly distributed into three groups of self-etching adhesive systems: Clearfil™ SE Bond containing 5% QAMP (experimental group), Clearfil™ Protect Bond (positive control) and Clearfil™ SE Bond (negative control). After light curing, three 1 mm-increments of composite resin were bonded to each dentin surface. A total of thirty of these bonded teeth (10 teeth per group) was sectioned to obtain stick-shaped specimens and tested under tensile stress immediately, and after 6 and 12 months of storage in distilled water. Twelve bonded teeth (4 teeth per group) were longitudinally sectioned in a mesio-to-distal direction to obtain resin-bonded dentin slabs. In situ DC was evaluated by micro-Raman spectroscopy. In vitro DC of thin films of each adhesive system was measured using Fourier transform infrared spectroscopy. In vitro susceptibility tests of these three adhesive systems were performed by the minimum inhibitory/minimum bactericidal concentration (MIC/MBC) assays against Streptococcus mutans, Lactobacillus casei, and Actinomyces naeslundii. No statistically significant difference in μTBS was observed between Clearfil™ SE Bond containing 5% QAMP and Clearfil™ SE Bond (p > 0.05) immediately, and after 6 and 12 months of water storage. However Clearfil™ Protect Bond showed a significant reduction of μTBS after 12 months of storage (p = 0.039). In addition, QAMP provided no significant change in DC after incorporating into Clearfil™ SE Bond (p > 0.05). Clearfil™ SE Bond containing 5% QAMP demonstrated MIC/MBC values similar to the positive control against L. casei and A. naeslundii and higher than the negative control for all evaluated bacterial strains. The use of QAMP in an adhesive system demonstrated effective bond strength, a suitable degree of conversion, and adequate antibacterial effects against oral bacteria, and may be useful as a new approach to provide long-lasting results for dental adhesives.

Graphical Abstract

1. Introduction

The risk of recurrent caries can be increased by residual bacteria in tooth restoration, which remains a challenge in dentistry [1,2]. In order to avoid this adverse condition, adhesive systems should present a long-lasting antibacterial activity for bacteria that enter this interface, leading to microleakage [13]. Accordingly, some antimicrobials freely dispersed into adhesive systems such as antibiotics, quaternary ammonium compounds glutaraldehyde, and fluorides have been extensively evaluated [411]. However these freely dispersed agents are inappropriately released from restorative material and result in decreased bond strength for restoration [11,12].
Other studies assessed the use of quaternary ammonium-based antibacterial monomers into dental resins such as 1,2-methacryloyloxydodecylpyridinium bromide (MDPB) [1321]. MDPB was first synthesized 20 years ago and demonstrated antibacterial activity against Streptococcus mutans, Lactobacillus casei, and Actinomyces naeslundii [2124]. This monomer was incorporated into an adhesive system and is now commercially available as Clearfil™ Protect Bond [20].
Despite that the use of quaternary ammonium monomers into adhesive systems can be considered a feasible approach, some studies have reported limitations in their use. Feuerstein et al. [1] performed a study to investigate the immediate and long-lasting antibacterial properties of four self-etching adhesive systems, including Clearfil™ Protect Bond for 14 days. Clearfil™ Protect Bond exhibited an antibacterial effect for only seven days. Moreover, no adhesive system showed antibacterial effect against S. mutans in 14 days. Thus the MDPB molecules that were not polymerized were leached out of the adhesive system leading to a higher antibacterial effect but only in a reduced time interval. In addition, quaternary ammonium compounds of low molecular weight as MDPB can have cytotoxicity to human pulp cells, which compromises their clinical safety [24,25].
Novel antimicrobial agents are needed and much work has been devoted to developing highly efficient compounds that are also less susceptible to development of resistance by bacteria [26]. In a previous paper, our group successfully synthesized an innovative quaternary ammonium methacrylate polymer (QAMP), a poly(dimethylaminoethyl methacrylate-co-octyldimethyl ammonium ethyl methacrylate bromide-co-methyl methacrylate-co-butyl methacrylate) (Figure 1) [27]. Quaternary ammonium methacrylate polymer (QAMP) was properly characterized by Fourier transformed infrared spectroscopy, nuclear magnetic resonance spectroscopy, wide-angle X-ray powder diffraction, and thermogravimetric analysis and was then incorporated into a self-etching adhesive system [27]. The self-etching adhesive containing QAMP had antibacterial activity against S. mutans and was particularly recommended for reducing recurrent caries. Due to its high molecular weight, QAMP demonstrated a lower migration from the adhesive system compared to MDPB [27]. In addition, QAMP is a non-volatile and chemically stable polymer that is not permeable through the oral mucosa in contrast to the main problems of the chemically-related quaternized monomers [25]. However, further studies are required to evaluate the behavior of QAMP in adhesive systems concerning their physicochemical properties, e.g., resin–dentin bond strength (μTBS) and degree of conversion (DC) which are strongly related to dental restoration longevity. In addition, its antibacterial potential against other oral bacteria that compromise the durability of composite resin restorations remains unknown.
The microtensile test is a laboratory procedure used to quantify the bond strength of adhesive biomaterials to tooth substrates [29]. This assay shows a pre-clinical value for dental adhesives, based on the assumption that the stronger the tooth-biomaterial adhesion, the more effectively it will resist the stress imposed by polymerization shrinkage of the composite resin [30]. The composite resin generates contraction stresses that affect the cavity margin. In clinical situations, these stresses are responsible for the composite pulling away from the margin and create a marginal gap [31]. This detachment of the composite resin from the dental hard tissues can result in postoperative sensitivity, enamel cracking, recurrent caries, marginal discoloration and finally failure of the restoration [31,32]. The microtensile test can also provide insights about the strength of adhesion of restorative materials used in dentistry as a function of time [33].
The degree of conversion plays a crucial role in the long-lasting resin/dentin bond study due to monomer conversion after polymerization of light-cured materials, which can affect various mechanical properties of the adhesive system including the tensile, compressive, and flexural strengths, elastic modulus, wear, and hardness. High DC can also reduce permeability at the bond interface, which increases resistance to degradation [34]. Moreover an incomplete polymerization of adhesive monomers has been reported as one of the reasons for nanoleakages [35].
Antibacterial evaluation plays an important role during the development of newer restorative materials in order to provide additional properties for preventing and treating caries lesions [16]. The ability to control bacteria is required to eliminate the risk of further demineralization and cavitation, since dental caries is an infectious disease and its eradication is crucial for improving the durability of restorations [16]. Regarding the in vitro susceptibility tests, agar-disc diffusion is a traditional method that can be used. However its results do not distinguish whether the restorative materials exhibit bactericidal or bacteriostatic effects; further, the production of inhibition zones on the agar plate indicates only that bacterial growth was hindered [20]. In that sense, minimum inhibitory/bactericidal concentrations (MIC/MBC) are currently more recommended due to their quantification of intrinsic antibacterial activity that provides more suitable data for evaluating eradication of pathogenic oral bacteria, prevention of caries lesions and longevity of dental restorations [20].
Considering these factors, the objective of this paper was to characterize the QAMP by micro-Raman spectroscopy and to investigate μTBS and DC of a self-etching adhesive system containing QAMP in order to explore whether this quaternary ammonium methacrylate polymer can affect the dental restoration longevity. The null-hypothesis tested was that there is no difference in bond characteristics and degree of conversion among the primer/bond-resin containing QAMP and other control groups. Furthermore, this paper also aimed at assessing the in vitro antibacterial effect of a commercial adhesive system containing QAMP against the usual pathogenic oral bacteria for evaluating its potential on preventing caries lesions.

2. Results

2.1. Micro-Raman Spectroscopy of Quaternary Ammonium Methacrylate Polymer (QAMP)

Raman spectra of the QAMP and raw materials (Eudragit™ E100 and n-octyl bromide) are presented in Figure 2. Eudragit™ E100 showed a C–N stretching band at 602 cm−1. An assignment at 818 cm−1 corresponded to C–C stretching vibration [36]. A Raman band at 1450 cm−1 was attributed mainly to –CH2– scissoring modes. A typical band at 1728 cm−1 was assigned to C=O ester stretching. Dimethylamino groups led to bands at 2772 and 2821 cm−1. A strong band due to C–H stretching was observed at 2944 cm−1. The Raman spectrum of this polymer also displayed bands at 1192, 1123, and 967 cm−1, which were associated with C–H and C–C wagging vibration [37]. Concerning n-octyl bromide, its Raman spectrum showed a typical band corresponding to C–Br stretching between 560 and 650 cm−1. In addition, vibrations of –CH2– and –CH3 groups were assigned at 1440 cm−1. Strong bands due to C–H stretching were observed between 2850 and 3000 cm−1.
Considering the spectrum of QAMP, Raman bands appeared at 3030 cm−1 (a1) as a broadening of C–H alkyl stretching bands. A novel band attributed to the symmetric stretching vibration of octyl dimethyl ammonium substituent was verified at 726 cm−1 (a2). These Raman bands were particularly related to the formation of the quaternary ammonium methacrylate polymer since these assignments were not previously observed in Eudragit™ E100 and n-octyl bromide. Similar Raman shifts were reported by Pigorsch et al. [38] in a study evaluating the spectroscopic characterization of cationic quaternary ammonium starches. As expected, the C–Br stretching vibration presented in n-octyl bromide between 560 and 650 cm−1 (b) disappeared in QAMP. Moreover Raman bands associated with dimethylamino groups of Eudragit™ E100, previously observed at 2772 and 2821 cm−1 (c), also disappeared. These Raman bands support an experimental basis for affirming that the quaternary ammonium methacrylate polymer was successfully synthesized. These data also reinforce the spectroscopic characterization previously performed by FTIR and described in our previous study [30].

2.2. Resin–Dentin Bond Strength (μTBS)

The results of μTBS (MPa) are summarized in Table 1. The mean cross-sectional area ranged from 0.80 to 0.95 mm2 and no difference among groups was verified (p > 0.05). Two-way ANOVA revealed that the interaction adhesive system vs. storage period was statistically significant (p = 0.02). A significant decrease on μTBS value was achieved for Clearfil™ Protect Bond after 12 M in water storage (p = 0.039). However, QAMP provided no statistical changes in μTBS after its incorporation into Clearfil™ SE Bond when compared to the negative control (p > 0.05). The percentage of specimens with premature debonding and the frequency of each fracture mode are shown in Table 2. The major fracture mode was adhesive/mixed for the three adhesive systems under study immediately, and after 6 and 12 months of storage in distilled water.

2.3. In Situ Analysis of Degree of Conversion (DC)

Figure 3 shows representative spectra of the evaluated adhesive systems in uncured and cured conditions. Mean and standard deviation values of in situ DC (%) of the experimental groups are reported in Table 3. The adhesives Clearfil™ SE Bond containing 5% QAMP, Clearfil™ Protect Bond, and Clearfil™ SE Bond presented similar DC means (p > 0.05).

2.4. In Vitro Analysis of Degree of Conversion (DC)

In vitro DC (%) of Clearfil™ SE Bond containing 5% QAMP, Clearfil™ Protect Bond, and Clearfil™ SE Bond is indicated in Table 4. Considering ATR-FTIR data, the investigated self-etching adhesive systems demonstrated similar DC values (p > 0.05).

2.5. In Vitro Antibacterial Evaluation

The MIC and MBC values for the three bacterial strains are shown in Table 5. In all tests, the same endpoint was obtained for each of three replicates. Clearfil™ SE Bond containing 5% QAMP showed MIC values of 20 μL/mL for S. mutans and A. naeslundii and 10 μL/mL for L. casei. These results were lower than that verified for the Clearfil™ SE Bond, which presented MIC values of 80 μL/mL or higher. The positive control (Clearfil™ Protect Bond) was more effective than the experimental group only against S. mutans, demonstrating a MIC value of 10 μL/mL. For L. casei and A. naeslundii, Clearfil™ SE Bond containing 5% QAMP presented similar bacteriostatic effects to Clearfil™ Protect Bond.
Concerning the bactericidal effect, the three adhesive systems showed MBC values at the same concentration levels observed in MIC assay against S. mutans and A. naeslundii. Considering L. casei, MBC was higher than MIC for the experimental adhesive and controls. As previously observed for MIC, the bactericidal performance of Clearfil™ SE Bond containing 5% QAMP was also similar to the positive control against L. casei and A. naeslundii and higher than the negative control for all evaluated bacterial strains.

3. Discussion

Bond tests have been extensively used for investigating the performance of adhesive systems in order to improve strategies for increasing the durability of resin–dentin bonds [39]. The rationale is that a stronger adhesion between tooth and biomaterial can provide a better response to the resulting stress of resin polymerization and oral function. Several factors can affect the adhesive performance including heterogeneity of the dentin structure, changes on dentin surface after performing bur cutting and chemical treatments, inappropriate bond strategy, insufficient co-polymerization between adhesive and composite resin, etc. [39,40]. Therefore, it is imperative that new adhesives should be carefully evaluated regarding their bond properties before use in further clinical studies. Accordingly, this study reports that QAMP, a new antibacterial additive for self-etching adhesive systems, did not affect microtensile bond strength or the degree of conversion of a widely-used commercial adhesive. Thus the null-hypothesis was accepted.
In general, the experimental groups of adhesive systems demonstrated suitable μTBS values. However Clearfil™ Protect Bond showed a statistically significant decrease of μTBS after 12 months in water storage. The scientific literature reports that a long-lasting adhesive effect can be decreased by the release of agents from cured adhesive systems resulting in a low durability of restoration [16]. In a previous study, our research group demonstrated that Clearfil™ Protect Bond provided a rapid release of 47.2% of MDPB while Clearfil™ SE Bond containing QAMP showed a mean release of 5.1% of quaternary ammonium compounds after 30 days [27]. In addition, Clearfil™ Protect Bond contains a fluoride-containing adhesive that can also be released. Therefore the major release of chemical compounds from Clearfil™ Protect Bond such as MDPB and fluoride can be involved in the significant reduction of microtensile bond strength verified after the storage interval of 12 months.
Concerning the fracture mode, adhesive/mixed failures were mainly observed for the investigated adhesive systems and a low percentage of cohesive failure in dentin occurred only for Clearfil™ SE Bond containing 5% QAMP after 6 M and Clearfil™ Protect Bond after 6 and 12 months. According to the literature, this behavior is required for commercial adhesive systems when submitted to μTBS measurements since it indicates that the strength was applied to the resin–dentin interface and not to one of these substrates alone. In addition, these results indicate that the methods used for performing μTBS as cross-head speeds were suitably chosen.
Considering the micro-Raman spectroscopy analysis carried out for adhesive systems, the aromatic band (1609 cm−1) is typically used as an internal standard and no change is noticeable after polymerization [41]. On the other hand, changes in intensity of the aliphatic band (1639 cm−1) are due to a decrease in the number of remaining C=C double bonds during the polymerization process [40]. In particular, this usual behavior was observed for Clearfil™ SE Bond containing 5% QAMP in which no change in the in situ DC was verified. Additionally, Clearfil™ Protect Bond and Clearfil™ SE Bond showed DC values as previously reported [42,43]. These values were higher than 80% and can be related to the sample preparation that uses water for cutting procedure which can wash the unreacted monomer and can lead to increased results [42,43]. Considering that the same sample preparation was used for all groups, it is possible to conclude that the addition of QAMP to the commercial adhesive showed no influence on in situ DC, resulting in a suitable curing.
The in vitro approach carried out by ATR-FTIR also confirmed that QAMP did not significantly change the DC value of Clearfil™ SE Bond after its incorporation at a concentration of 5%. However, these results were remarkably lower than that obtained by the in situ procedure which can be strongly related to the particular in vitro conditions. Clearfil™ SE Bond results in an acid solution (pH near 2) and shows high water content in vitro, which can impair the polymerization reaction of the adhesive system [44]. On the other hand, the self-etching acidic primer can be buffered by the mineral content of dentin and enamel when applied to the tooth surface [43], which allows higher monomer conversion.
Innovative restorative materials with particular biological functions are not clinically useful if their original properties are effectively changed [18]. In this study, QAMP showed suitable response in a commercial adhesive system containing MDP, HEMA, and Bis-GMA as monomers in terms of μTBS and DC. Tests to assess DC over time after incorporating QAMP into self-etching adhesive systems should be performed in a future work.
Considering MIC/MBC results, Clearfil™ SE Bond containing 5% QAMP demonstrated similar bacteriostatic/bactericidal effects as the positive control (Clearfil™ Protect Bond) against L. casei and A. naeslundii which are pathogenic oral bacteria directly involved in caries and gingivitis, respectively. The positive control had better antibacterial effect than the experimental group only for S. mutans. This result can be related to the presence of fluoride in Clearfil™ Protect Bond, which might have provided an additional antibacterial effect. Moreover, QAMP was effective in conferring high antibacterial effects to Clearfil™ SE Bond by comparing the MIC/MBC results before and after its incorporation. Furthermore, an adhesive system containing QAMP demonstrated a lower release of quaternary compounds than the commercial MDPB-containing one [27], which can be considered an advantage in terms of prolonging the durability of the restoration and reducing toxicity to oral tissues. A further aspect to be highlighted is the antibacterial effect provided by the quaternary ammonium compounds fixed in the adhesives and the amount that was leached to the liquid medium. According to our experimental conditions, these two contributions were considered for MIC/MBC results. Further antimicrobial tests have to be performed in order to evaluate the influence of the leached compounds in the antimicrobial properties of these adhesive systems.
The clinical performance of new adhesive systems containing different chemical components must be investigated using the survival rates of restorations placed in non-carious cervical lesions [44,45]. Furthermore, discoloration and marginal integrity have to be evaluated since failure of restoration margin is a common reason for the replacement and repair of composite restorative [45]. Therefore clinical studies should be made in order to confirm these in vitro results after incorporating QAMP into adhesives.

4. Materials and Methods

4.1. Micro-Raman Spectroscopy of the Quaternary Ammonium Methacrylate Polymer (QAMP)

Micro-Raman spectroscopy was used for characterizing QAMP. Raman spectra of QAMP and raw materials (Eudragit™ E100 and n-octyl bromide) were collected at room temperature using a Bruker Raman Microscope Spectrometer (Bruker Optik GmbH, Ettlingen, Germany) with a 532 nm Nd:YAG laser line (20 mW) as an excitation source. Analysis were performed according to the following experimental parameters: charge-coupled device detector cooled at 208 K; spectral resolution of 3–5 cm−1; power on the sample of 2 mW; scanning range of 4000–200 cm−1; accumulation time of 20 s and scan number of 4. Opus spectroscopy software (version 6.5, Bruker Optik, Natick, MA, USA) was used to process the collected data.

4.2. Experimental Groups and Restorative Procedures

Three self-etching adhesive systems were evaluated: Clearfil™ SE Bond containing 5% QAMP, Clearfil™ Protect Bond (Kuraray Medical, Kurashiki, Japan) as positive control and Clearfil™ SE Bond (Kuraray Medical, Kurashiki, Japan) as negative control. Detailed composition and application mode of these commercial adhesive systems are described in Table 6.
The self-etching adhesive systems were applied onto the dentin in accordance with the manufacturer’s instructions. After light curing of each adhesive, three 1 mm-increments of composite resin Filtek™ Z350 XT (3M ESPE, St. Paul, MN, USA) were bonded to each dentin surface. Each increment was light cured with LED (LED Radii-cal, SDI, São Paulo, Brazil) for 30 s at 600 mW/cm2. All bond procedures were carried out by a single operator at room temperature and constant relative humidity.

4.3. Teeth Selection and Preparation

A total of forty-two extracted caries-free human third molars were used. Microtensile bond strength (μTBS) was performed using 30 teeth whereas analysis of in situ degree of conversion (DC) was carried out with 12 teeth. These teeth were collected after obtaining the patients’ informed consent under Protocol Number #17839/10 that was approved (#35/2011) by the Ethics Committee on Research Involving Human Subjects from the State University of Ponta Grossa, on 6 April 2011. The teeth were disinfected using 0.5% chloramine, stored in distilled water, and used within six months after extraction. A flat dentin surface was exposed after wet grinding the occlusal enamel on #180-grit silicon-carbide (SiC) paper. The exposed dentin surfaces were further polished on wet #600-grit SiC paper for 60 s to create a standardized smear layer.

4.4. Resin–Dentin Bond Strength (μTBS)

After storing the bonded teeth in distilled water for 24 h at 37 °C, thirty teeth (10 teeth per group) were longitudinally sectioned in both the mesio-distal and buccal-lingual directions across the bonded interface using a diamond saw in an Isomet 1000 machine (Buehler Ltd., Lake Bluff, IL, USA) at 300 rpm in order to obtain bonded sticks with a cross-sectional area of approximately 0.8 mm2. The number of premature debonded sticks per tooth during specimen preparation was recorded. The cross-sectional area of each stick was measured with a digital caliper (Absolute Digimatic, Mitutoyo, Tokyo, Japan). The bonded sticks of each tooth were divided to be tested immediately, after 6 and 12 months of storage in distilled water containing 0.4% sodium azide at 37 °C. The storage solution was not changed during μTBS experiments [46].
At each storage period, an individual bonded stick was attached to a Geraldelli’s device for μTBS using cyanoacrylate resin (Super Bonder Gel, Loctite, Piracicaba, Brazil). Each stick was stressed to failure using a universal testing machine (Kratos Dinamometros, São Paulo, Brazil) at a crosshead speed of 0.5 mm/min. Failure modes were evaluated in a light stereomicroscope (Nikon Eclipse E200, Melville, NY, USA) at 40× magnification and were classified as cohesive (failure exclusively within dentin or resin composite, C), adhesive (failure at resin/dentin interface, A), and adhesive/mixed (failure at resin/dentin interface that included cohesive failure of the neighboring substrates, A/M).
All tested sticks from the same tooth were averaged for statistical purposes. The prematurely debonded specimens were included in tooth mean. For each experimental group, μTBS mean was then obtained. Data were analyzed using two-way ANOVA (adhesive system and storage period) and Games Howell’s post-hoc test (α = 0.05) for pair-wise comparisons.

4.5. In Situ Analysis of Degree of Conversion (DC)

Twelve bonded third molars (4 teeth per group) were longitudinally sectioned in a mesio-to-distal direction across the bonded interface using a diamond saw in an Isomet 1000 machine at 300 rpm to prepare 2.0 mm resin-bonded dentin slices. Two slices from the center of each tooth were selected for the micro-Raman analysis.
The resin-bonded dentin slices (n = 8 for each experimental group) were individually and manually polished using SiC papers of decreasing abrasiveness (#1000, #1200, #1500, and #2000 grits). Specimens were ultrasonically cleaned for 10 min and then stored in water for 24 h at 37 °C before performing the analysis of DC.
Raman spectra were collected at room temperature using a computer-controlled laser Raman microscope spectrometer (Senterra, Bruker Optik, Ettlingen, Baden-Württemberg, Germany) with a 532 nm neodymium:yttrium-aluminium-garnet (Nd:YAG) laser line (20 mW) as an excitation source. Analyses were performed according to the following experimental parameters: charge-coupled device detector cooled at 208 K, spatial resolution of ≈3 μm, spectral resolution of ≈5 cm−1, power on the sample of 2 mW, scanning range of 1750–280 cm−1, accumulation time of 30 s and 6 co-additions, and 100× magnification (Olympus, London, UK) to a ≈1 μm beam diameter [35]. Spectra were taken in the middle of the hybrid layer, in an arbitrary area of the intertubular dentin. Two sites were examined per each dentin-adhesive slice.
Raman spectra of uncured adhesives were collected to identify the characteristic bands. Measurements were recorded three times with different specimens for each self-etching adhesive system. Opus spectroscopy software (version 6.5, Bruker Optik) was used to process the collected data. The double-bond content for converting monomer to polymer of each adhesive was calculated using the ratio between cured and uncured band intensities (Equation (1)):
% conversion = 1 - { R ( cured ) R ( uncured ) } × 100 %
where “R” is the ratio between aliphatic and aromatic band intensities at 1639 and 1609 cm−1 for cured and uncured adhesives.
Considering that the obtained values were normally distributed (Kolmogorov–Smirnof test), DC (%) was evaluated using a one-way ANOVA and Tukey’s post-hoc test (α = 0.05).

4.6. In Vitro Analysis of Degree of Conversion (DC)

The in vitro DC was investigated by Fourier transform infrared spectroscopy (FTIR) with an attenuated total reflectance (ATR) device (Spectrum 100, PerkinElmer, Shelton, CT, USA) at 24 °C, under 64% relative humidity. The self-etching adhesive systems evaluated were: Clearfil™ SE Bond containing 5% QAMP, Clearfil™ Protect Bond and Clearfil™ SE Bond (negative control). In order to obtain DC, three samples of each uncured adhesive system and five thin films (0.2–0.3 mm thick) of each cured adhesive were applied on the plate with ZnSe crystal for acquiring the absorption spectra.
The absorption spectra of cured and uncured adhesive systems were collected from 4000 to 650 cm−1 with 32 scans at 4 cm−1. The ratio between band intensities of C=C aliphatic methacrylate group (1639 cm−1) and the reference C···C aromatic ring (1609 cm−1) was obtained for cured and uncured adhesives. The DC (%) was than calculated using Equation 1. Data were analyzed by one-way ANOVA and Tukey’s post-hoc test (α = 0.05). The SPSS Statistics software, version 20.0 (SPSS Statistics, IBM Corporation, Somers, NY, USA) was used to perform all the statistical analysis in this study.

4.7. In Vitro Antibacterial Evaluation

The antibacterial properties of Clearfil™ SE Bond containing 5% QAMP and controls were investigated by in vitro susceptibility tests of minimum inhibitory/minimum bactericidal concentrations as previously reported [25,27,47].
In brief, plates containing Mueller-Hinton (MH) agar with 5% sheep blood were inoculated with strains of Streptococcus mutans (ATCC 25175), Lactobacillus casei (ATCC 393), and Actinomyces naeslundii (ATCC 12104) from previously standardized inocula at a concentration of 5 × 105 CFU/mL that achieved the turbidity of 0.5 at McFarland scale (1.5 × 108 CFU/mL) by swab streaking [39,40]. Volumes of 10, 20, 40, and 80 μL of Clearfil™ SE Bond containing 5% QAMP, obtained by using equal aliquots of primer and bond, positive and negative controls were spread onto the bottom of hemolysis tubes, air-thinned and light-cured with light-emitting diode (LED) for 20 s [17]. The final volume and exposed surface area were not controlled during the in vitro antibacterial experiments. Afterwards, 1 mL of brain-heart infusion (BHI) broth containing cultures of each microorganism at a concentration of 5 × 105 CFU/mL was added. These tubes were shaken once after addition of BHI broth and cultured under microaerophilic conditions (5% O2, 10% CO2, 85% N2) during 24 h at 35 ± 0.5 °C [48]. The bacterial growth was estimated by changes in optical density (OD) considering the measurements taken before and after incubation. For OD evaluation, 200 μL of each culture medium was transferred to a 96-well microplate and the absorbance was measured at 450 nm using a spectrophotometric plate reader (EL800, Bio-tek Instruments, Winooski, VT, USA). Tests were performed in triplicate with fresh BHI serving as blank control. The minimum inhibitory concentration (MIC) was defined as the endpoint where no turbidity might be detected with respect to the controls.
In order to determine the minimum bactericidal concentration (MBC), subcultures were obtained by spreading a 100 μL-aliquot from each test tube without turbidity on Mueller-Hinton agar plates supplemented with 5% sheep blood. Plates were incubated under microaerophilic conditions for 24 h at 35 ± 0.5 °C. The MBC value was determined as the lowest concentration of each adhesive system that provided no bacterial growth.

5. Conclusions

In summary, the experimental results demonstrated that QAMP did not change the required adhesive properties of resin–dentin bond strength and degree of conversion and further provided antibacterial effects for the evaluated adhesive system against usual pathogenic oral bacteria. These data support a promising potential for the use of quaternary ammonium methacrylate polymers in dental adhesive to promote the additional advantages of preventing caries lesions and prolonging the durability of dental restorations.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Feuerstein, O.; Matalon, S.; Slutzky, H.; Weiss, E.I. Antibacterial properties of self-etching dental adhesive systems. J. Am. Dent. Assoc 2007, 138, 349–354. [Google Scholar]
  2. Walter, R.; Duarte, W.R.; Pereira, P.N.R.; Heymann, H.O.; Swift, E.J., Jr.; Arnold, R.R. In vitro inhibition of bacterial growth using different dental adhesive systems. Oper. Dent 2007, 32, 388–393. [Google Scholar]
  3. Imazato, S.; Imai, T.; Russell, R.R.; Torii, M.; Ebisu, S. Antibacterial activity of cured dental resin incorporating the antibacterial monomer MDPB and an adhesion-promoting monomer. J. Biomed. Mater. Res 1998, 39, 511–515. [Google Scholar]
  4. Bapna, M.S.; Murphy, R.; Mukherjee, S. Inhibition of bacterial colonization by antibacterial agents incorporated into dental resins. J. Oral Rehabil 1988, 15, 405–411. [Google Scholar]
  5. Kudou, Y.; Obara, K.; Kawashima, T.; Kubota, M.; Abe, S.; Endo, T.; Komatsu, M.; Okuda, R. Addition of antibacterial agents to MMA-TBB dentin bonding systems-influence on tensile bond strength and antibacterial effect. Dent. Mater. J 2000, 19, 65–74. [Google Scholar]
  6. Imazato, S.; Kuramoto, A.; Kaneko, T.; Ebisu, S.; Russell, R.R. Comparison of antibacterial activity of simplified adhesive systems. Am. J. Dent 2002, 15, 356–360. [Google Scholar]
  7. Kazuno, T.; Fukushima, T.; Hayakawa, T.; Inoue, Y.; Ogura, R.; Kaminishi, H.; Miyazaki, K. Antibacterial activities and bonding of MMSA/TBB resin containing amphiphilic lipids. Dent. Mater. J 2005, 24, 244–250. [Google Scholar]
  8. Fang, M.; Chen, J.H.; Xu, X.L.; Yang, P.H.; Hildebrand, H.F. Antibacterial activities of inorganic agents on six bacteria associated with oral infections by two susceptibility tests. Int. J. Antimicrob. Agents 2006, 27, 513–517. [Google Scholar]
  9. Fang, M.; Chai, F.; Chen, J.H.; Neut, C.; Jia, M.; Liu, Y.; Zhao, S.J.; Hildebrand, H.F. Antibacterial functionalization of an experimental self-etching primer by inorganic agents: Microbiological and biocompatibility evaluations. Biomol. Eng 2007, 24, 483–488. [Google Scholar]
  10. Meiers, J.C.; Shook, L.W. Effect of disinfectants on the bond strength of composite to dentin. Am. J. Dent 1996, 9, 11–14. [Google Scholar]
  11. Moen, B.; Rudi, K.; Bore, E.; Langsrud, S. Subminimal inhibitory concentrations of the disinfectant benzalkonium chloride select for a tolerant subpopulation of Escherichia coli with inheritable characteristics. Int. J. Mol. Sci 2012, 13, 4101–4123. [Google Scholar]
  12. Gürgan, S.; Bolay, S.; Kiremitçi, A. Effect of disinfectant application methods on the bond strength of composite to dentin. J. Oral Rehabil 1999, 26, 836–840. [Google Scholar]
  13. Imazato, S.; Kinomoto, Y.; Tarumi, H.; Ebisu, S.; Tay, F.R. Antibacterial activity and bonding characteristics of an adhesive resin containing antibacterial monomer MDPB. Dent. Mater 2003, 19, 313–319. [Google Scholar]
  14. Imazato, S.; Kaneko, T.; Takahashi, Y.; Noiri, Y.; Ebisu, S. In vivo antibacterial effects of dentin primer incorporating MDPB. Oper. Dent 2004, 29, 369–375. [Google Scholar]
  15. Imazato, S.; Tay, F.R.; Kaneshiro, A.V.; Takahashi, Y.; Ebisu, S. An in vivo evaluation of bonding ability of comprehensive antibacterial adhesive system incorporating MDPB. Dent. Mater 2007, 23, 170–176. [Google Scholar]
  16. Imazato, S. Bio-active restorative materials with antibacterial effects: New dimension of innovation in restorative dentistry. Dent. Mater. J 2009, 28, 11–19. [Google Scholar]
  17. Li, F.; Chai, Z.G.; Sun, M.N.; Wang, F.; Ma, S.; Zhang, L.; Fang, M.; Chen, J.H. Anti-biofilm effect of dental adhesive with cationic monomer. J. Dent. Res 2009, 88, 372–376. [Google Scholar]
  18. Xiao, Y.H.; Ma, S.; Chen, J.H.; Chai, Z.G.; Li, F.; Wang, Y.J. Antibacterial activity and bonding ability of an adhesive incorporating an antibacterial monomer DMAE-CB. J. Biomed. Mater. Res. B 2009, 90, 813–817. [Google Scholar]
  19. Thomé, T.; Mayer, M.P.; Imazato, S.; Geraldo-Martins, V.R.; Marques, M.M. In vitro analysis of inhibitory effects of the antibacterial monomer MDPB-containing restorations on the progression of secondary root caries. J. Dent 2009, 37, 705–711. [Google Scholar]
  20. Imazato, S.; Kuramoto, A.; Takahashi, Y.; Ebisu, S.; Peters, M.C. In vitro antibacterial effects of the dentin primer of Clearfil Protect Bond. Dent. Mater 2006, 22, 527–532. [Google Scholar]
  21. Imazato, S.; Kawakami, M.; Torii, M.; Tsuchitani, Y. Antibacterial activity of composites containing chemically bound non-releasing antibacterial component. J. Dent. Res 1992, 72, 721. [Google Scholar]
  22. Imazato, S.; Torii, M.; Tsuchitani, Y.; McCabe, J.F.; Russell, R.R.B. Incorporation of bacterial inhibitor into resin composite. J. Dent. Res 1994, 73, 1437–1443. [Google Scholar]
  23. Imazato, S.; Russell, R.R.B.; McCabet, J.F. Antibacterial activity of MDPB polymer incorporated in dental resin. J. Dent 1995, 23, 177–181. [Google Scholar]
  24. Imazato, S.; Ebi, N.; Tarumi, H.; Russell, R.R.B.; Kaneko, T.; Ebisu, S. Bactericidal activity and cytotoxicity of antibacterial monomer MDPB. Biomaterials 1999, 20, 899–903. [Google Scholar]
  25. Lu, G.; Wu, D.; Fu, R. Studies on the synthesis and antibacterial activities of polymeric quaternary ammonium salts from dimethylaminoethyl methacrylate. React. Funct. Polym 2007, 67, 355–366. [Google Scholar]
  26. Carmona-Ribeiro, A.M.; de Melo Carrasco, L.D. Cationic antimicrobial polymers and their assemblies. Int. J. Mol. Sci 2013, 14, 9906–9946. [Google Scholar]
  27. Pupo, Y.M.; Farago, P.V.; Nadal, J.M.; Esmerino, L.A.; Maluf, D.F.; Zawadzki, S.F.; Michél, M.D.; Santos, F.A.; Gomes, O.M.M.; Gomes, J.C. An innovative quaternary ammonium methacrylate polymer can provide improved antibacterial properties for a dental adhesive system. J. Biomater. Sci. Polym. Ed 2013, 24, 1443–1458. [Google Scholar]
  28. Farago, P.V.; Pupo, Y.M.; Gomes, J.C. Processo de obtenção e uso de polímero metacrílico quaternário de amônio com propriedades antimicrobianas para a incorporação em materiais odontológicos. Brazil patent application number 10 2012 0266 4 18 December 2012. [Google Scholar]
  29. Poitevin, A.; de Munck, J.; van Landuyt, K.; Coutinho, E.; Peumans, M.; Lambrechts, P.; van Meerbeek, B. Critical analysis of the influence of different parameters on microtensile bond strength of adhesives to dentin. J. Adhes. Dent 2008, 10, 7–16. [Google Scholar]
  30. De Munck, J.; van Landuyt, K.; Peumans, M.; Poitevin, A.; Lambrechts, P.; Braem, M.; van Meerbeek, B. A critical review of the durability of adhesion to tooth tissue: Methods and results. J. Dent. Res 2005, 84, 118–132. [Google Scholar]
  31. Rullmann, I.; Schattenberg, A.; Marx, M.; Willershausen, B.; Ernst, C.P. Photoelastic determination of polymerization shrinkage stress in low-shrinkage resin composites. Schweiz. Monatsschr. Zahnmed 2012, 122, 294–299. [Google Scholar]
  32. Yamazaki, P.C.V.; Bedran-Russo, A.K.B.; Pereira, P.N.R.; Swift, E.J., Jr. Microleakage evaluation of a new low-shrinkage composite restorative material. Oper. Dent 2006, 31, 670–676. [Google Scholar]
  33. Pashley, D.H.; Carvalho, R.M.; Sano, H.; Nakajima, M.; Yoshiyama, M.; Shono, Y.; Fernandes, C.A.; Tay, F. The microtensile bond test: A review. J. Adhes. Dent 1999, 1, 299–309. [Google Scholar]
  34. Miyazaki, M.; Onose, H.; Moore, B.K. Analysis of the dentin-resin interface by use of laser Raman spectroscopy. Dent. Mater 2002, 18, 576–580. [Google Scholar]
  35. Navarra, C.O.; Cadenaro, M.; Armstrong, S.R.; Jessop, J.; Antoniolli, F.; Sergo, V.; di Lenarda, R.D.; Breschi, L. Degree of conversion of Filtek Silorane Adhesive System and Clearfil SE Bond within the hybrid and adhesive layer: An in situ Raman analysis. Dent. Mater 2009, 25, 1178–1185. [Google Scholar]
  36. Karamoddini, M.K.; Fazli-Bazzaz, B.S.; Emamipour, F.; Ghannad, M.S.; Jahanshahi, A.R.; Saed, N.; Sahebkar, A. Antibacterial efficacy of lytic bacteriophages against antibiotic-resistant Klebsiella species. Sci. World J 2011, 11, 1332–1340. [Google Scholar]
  37. Veij, M.; Vandenabeele, P.; Beer, T.; Remonc, J.P.; Moensa, L. Reference database of Raman spectra of pharmaceutical excipients. J. Raman Spectrosc 2009, 40, 297–307. [Google Scholar]
  38. Pigorsch, E. Spectroscopic characterization of cationic quaternary ammonium starches. Starch-Stärke 2009, 61, 129–138. [Google Scholar]
  39. Carvalho, R.M.; Manso, A.P.; Geraldeli, S.; Tay, F.R.; Pashley, D.H. Durability of bonds and clinical success of adhesive restorations. Dent. Mater 2012, 28, 72–86. [Google Scholar]
  40. Van Landuyt, K.L.; Snauwaert, J.; de Munck, J.; Peumans, M.; Yoshida, Y.; Poitevin, A.; Coutinho, E.; Suzuki, K.; Lambrechts, P.; van Meerbeek, B. Systematic review of the chemical composition of contemporary dental adhesives. Biomaterials 2007, 28, 3757–3785. [Google Scholar]
  41. Hass, V.; Luque-Martinez, I.; Sabino, N.B.; Loguercio, A.D.; Reis, A. Prolonged exposure times of one-step self-etch adhesives on adhesive properties and durability of dentine bonds. J. Dent 2012, 40, 1090–1102. [Google Scholar]
  42. Marchesi, G.; Navarra, C.O.; Cadenaro, M.; Carrilho, M.R.; Codan, B.; Sergo, V.; di Lenarda, R.; Breschi, L. The effect of ageing on the elastic modulus and degree of conversion of two multistep adhesive systems. Eur. J. Oral Sci 2010, 118, 304–310. [Google Scholar]
  43. Arrais, C.A.; Pontes, F.M.; Santos, L.P.; Leite, E.R.; Giannini, M. Degree of conversion of adhesive systems light-cured by LED and halogen light. Braz. Dent. J 2007, 18, 54–59. [Google Scholar]
  44. Tay, F.R.; Pashley, D.H. Aggressiveness of contemporary self-etching systems. I: Depth of penetration beyond dentin smear layers. Dent. Mater 2001, 17, 296–308. [Google Scholar]
  45. Chee, B.; Rickman, L.J.; Satterthwaite, J.D. Adhesives for the restoration of non-carious cervical lesions: A systematic review. J. Dent 2012, 40, 443–452. [Google Scholar]
  46. Kitasako, Y.; Burrow, M.F.; Nikaido, T.; Tagami, J. The influence of storage on dentin bond durability of resin cement. Dent. Mater 2000, 16, 1–6. [Google Scholar]
  47. Xiao, Y.H.; Chen, J.H.; Fang, M.; Xing, X.D.; Wang, H.; Wang, Y.J.; Li, F. Antibacterial effects of three experimental quaternary ammonium salts (QAS) monomers on bacteria associated with oral infections. J. Oral Sci 2008, 50, 323–327. [Google Scholar]
  48. Clinical and Laboratory Standards Institute (CLSI), Performance standards for antibacterial susceptibility testing; Twenty-first informational supplement. In CLSI Document M100-S21; Clinical and Laboratory Standards Institute: Wayne, PA, USA, 2011.
Figure 1. Chemical structure of the quaternary ammonium methacrylate polymer (QAMP) [Brazil patent application number 10 2012 0266 4] [28].
Figure 1. Chemical structure of the quaternary ammonium methacrylate polymer (QAMP) [Brazil patent application number 10 2012 0266 4] [28].
Ijms 15 08998f1
Figure 2. Raman spectra of QAMP and raw materials (Eudragit™ E100 and n-octyl bromide). (a1) Raman band at 3030 cm−1 as a broadening of C–H alkyl stretching bands; (a2) A novel band attributed to the symmetric stretching vibration of octyl dimethyl ammonium substituent was verified at 726 cm−1; (b) The C–Br stretching vibration presented in n-octyl bromide between 560 and 650 cm−1 disappeared in QAMP; and (c) Raman bands associated with dimethylamino groups of Eudragit™ E100, previously observed at 2772 and 2821 cm−1 also disappeared.
Figure 2. Raman spectra of QAMP and raw materials (Eudragit™ E100 and n-octyl bromide). (a1) Raman band at 3030 cm−1 as a broadening of C–H alkyl stretching bands; (a2) A novel band attributed to the symmetric stretching vibration of octyl dimethyl ammonium substituent was verified at 726 cm−1; (b) The C–Br stretching vibration presented in n-octyl bromide between 560 and 650 cm−1 disappeared in QAMP; and (c) Raman bands associated with dimethylamino groups of Eudragit™ E100, previously observed at 2772 and 2821 cm−1 also disappeared.
Ijms 15 08998f2
Figure 3. Micro-Raman spectras of uncured and cured adhesive systems Clearfil™ SE Bond containing 5% QAMP, Clearfil™ Protect Bond, Clearfil™ SE Bond. The reference band is shown at 1609 cm−1 and the reactive band related to C=C group is indicated at 1639 cm−1 (arrows). This band decreases during polymerization and was used for calculating the degree of conversion.
Figure 3. Micro-Raman spectras of uncured and cured adhesive systems Clearfil™ SE Bond containing 5% QAMP, Clearfil™ Protect Bond, Clearfil™ SE Bond. The reference band is shown at 1609 cm−1 and the reactive band related to C=C group is indicated at 1639 cm−1 (arrows). This band decreases during polymerization and was used for calculating the degree of conversion.
Ijms 15 08998f3aIjms 15 08998f3b
Table 1. Mean and standard deviation values of overall resin-dentin bond strength (MPa) from the evaluated adhesive systems.
Table 1. Mean and standard deviation values of overall resin-dentin bond strength (MPa) from the evaluated adhesive systems.
Adhesive systemStorage period

Immediately6 months12 months
Clearfil™ SE Bond containing 5% QAMP34.88 ± 8.71 Aa33.43 ± 5.47 Aa32.50 ± 5.94 Aa
Clearfil™ Protect Bond37.23 ± 6.71 Aa39.44 ± 3.25 Aa28.20 ± 8.09 Ba
Clearfil™ SE Bond34.69 ± 5.95 Aa32.08 ± 10.97 Aa31.27 ± 9.30 Aa
Groups identified with the same letters are not significantly different (Tukey’s test, p > 0.05), with uppercase letters (for each adhesive system) in rows or lowercase letters (for each storage period) in columns.
Table 2. Fracture mode and premature debonded specimens from the evaluated adhesive systems (*).
Table 2. Fracture mode and premature debonded specimens from the evaluated adhesive systems (*).
Adhesive systemStorage period

Immediately6 months12 months



A/MCDebondTA/MCDebondTA/MCDebondT
Clearfil™ SE Bond containing 5% QAMP36(80)0(0)9(20)4537(92.5)2(5)1(2.5)4034(94.5)0(0)2(5.5)36
Clearfil™ Protect Bond35(79.6)0(0)9(20.4)4435(83.3)1(2.4)6(14.3)4234(91.9)1(2.5)3(8.1)37
Clearfil™ SE Bond35(71.4)0(0)14(28.6)4935(81.4)0(0)8(18.6)4335(83.3)0(0)7(16.7)42
*Results are shown as number, percentage of specimens and total of sticks;
Legend: A/M, adhesive/mixed fracture mode; C, cohesive fracture mode; Debond, premature debonded specimens; T, total.
Table 3. Mean and standard deviation values of in situ analysis of degree of conversion (%) for adhesive systems.
Table 3. Mean and standard deviation values of in situ analysis of degree of conversion (%) for adhesive systems.
Adhesive systems
Clearfil™ SE Bond containing 5% QAMPClearfil™ Protect BondClearfil™ SE Bond
89 ± 6 a85 ± 11 a88 ± 3 a
Groups identified with the same lowercase letters are not significantly different (Tukey’s test, p > 0.05).
Table 4. Mean and standard deviation values of in vitro analysis of degree of conversion (%) for adhesive systems.
Table 4. Mean and standard deviation values of in vitro analysis of degree of conversion (%) for adhesive systems.
Adhesive systems
Clearfil™ SE Bond containing 5% QAMPClearfil™ Protect BondClearfil™ SE Bond
39.7 ± 2.9 a39.8 ± 4.9 a40.0 ± 3.0 a
Same lowercase letters indicate (p > 0.05) in columns.
Table 5. Minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) values for each adhesive system against three pathogenic oral bacteria.
Table 5. Minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) values for each adhesive system against three pathogenic oral bacteria.
Adhesive systemMIC/MBC values (μL/mL)

Streptococcus mutans (ATCC 25175)Lactobacillus casei (ATCC 393)Actinomyces naesludii (ATCC 12104)
Clearfil™ SE Bond containing 5% QAMP20/2010/2020/20
Clearfil™ Protect Bond10/1010/2020/20
Clearfil™ SE Bond80/8080/>8080/80
Table 6. Adhesive systems: composition (batch number) and application mode.
Table 6. Adhesive systems: composition (batch number) and application mode.
Adhesive systemsComposition (batch number)Application mode
Clearfil™ SE Bond containing 5% QAMPPrimer: MDP, HEMA, hydrophilic dimethacrylate, di-camphorquinone, N,N-diethanol-p-toluidine, water, QAMP. (00954A)
Bond: MDP, Bis-GMA, HEMA, hydrophobic dimethacrylate, di-camphorquinone, N,N-diethanol-p-toluidine, silanated colloidal silica. (01415A)
Application of two coats of the primer under pressure (20 s); Gentle air stream (10 s at 20 cm) after application of each coat; Application of one coat of the adhesive (15 s); Gentle air stream to make the bond film uniform (3 s at 20 cm); Light cured (10 s at 600 mW/cm2).
Clearfil™ Protect BondPrimer: MDPB, MDP, HEMA, hydrophilic dimethacrylate, water. (00081B)
Bond: MDP, HEMA, Bis-GMA, hydrophobic dimethacrylate, di-camphorquinone, N,N-diethanol-p-toluidine, silanated colloidal silica, surface-treated sodium fluoride. (00134B)
Clearfil™ SE BondPrimer: MDP, HEMA, hydrophilic dimethacrylate, di-camphorquinone, N,N-diethanol-p-toluidine, water. (00954A)
Bond: MDP, Bis-GMA, HEMA, hydrophobic dimethacrylate, di-camphorquinone, N,N-diethanol-p-toluidine, silanated colloidal silica. (01415A)
Abbreviations: MDP, 10-methacryloxydecyl dihydrogen phosphate; HEMA, 2-hydroxyethyl methacrylate; Bis-GMA, bisphenol-glycidyl methacrylate; MDPB, 12-methacryloyloxydodecyl pyridinium bromide; and QAMP, [poly(dimethylaminoethyl methacrylate-co-octyldimethylammonium ethyl methacrylate bromide-co-methyl methacrylate-co-butyl methacrylate)].

Share and Cite

MDPI and ACS Style

Pupo, Y.M.; Farago, P.V.; Nadal, J.M.; Simão, L.C.; Esmerino, L.A.; Gomes, O.M.M.; Gomes, J.C. Effect of a Novel Quaternary Ammonium Methacrylate Polymer (QAMP) on Adhesion and Antibacterial Properties of Dental Adhesives. Int. J. Mol. Sci. 2014, 15, 8998-9015. https://doi.org/10.3390/ijms15058998

AMA Style

Pupo YM, Farago PV, Nadal JM, Simão LC, Esmerino LA, Gomes OMM, Gomes JC. Effect of a Novel Quaternary Ammonium Methacrylate Polymer (QAMP) on Adhesion and Antibacterial Properties of Dental Adhesives. International Journal of Molecular Sciences. 2014; 15(5):8998-9015. https://doi.org/10.3390/ijms15058998

Chicago/Turabian Style

Pupo, Yasmine M., Paulo Vitor Farago, Jessica M. Nadal, Luzia C. Simão, Luís Antônio Esmerino, Osnara M. M. Gomes, and João Carlos Gomes. 2014. "Effect of a Novel Quaternary Ammonium Methacrylate Polymer (QAMP) on Adhesion and Antibacterial Properties of Dental Adhesives" International Journal of Molecular Sciences 15, no. 5: 8998-9015. https://doi.org/10.3390/ijms15058998

Article Metrics

Back to TopTop