<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="en" article-type="review-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">ijms</journal-id>
<journal-title>International Journal of Molecular Sciences</journal-title>
<abbrev-journal-title>Int. J. Mol. Sci.</abbrev-journal-title>
<issn pub-type="epub">1422-0067</issn>
<publisher>
<publisher-name>Molecular Diversity Preservation International (MDPI)</publisher-name></publisher></journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3390/ijms11010206</article-id>
<article-id pub-id-type="publisher-id">ijms-11-00206</article-id>
<article-categories>
<subj-group>
<subject>Review</subject></subj-group></article-categories>
<title-group>
<article-title>Photonic Methods to Enhance Fluorescence Correlation Spectroscopy and Single Molecule Fluorescence Detection</article-title></title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Wenger</surname><given-names>Jérome</given-names></name><xref ref-type="corresp" rid="c1-ijms-11-00206">⋆</xref></contrib>
<contrib contrib-type="author">
<name><surname>Rigneault</surname><given-names>Hervé</given-names></name></contrib>
<aff id="af1-ijms-11-00206">Institut Fresnel, Aix-Marseille Université, CNRS, Ecole Centrale Marseille, Domaine Universitaire de Saint-Jérôme, 13397 Marseille cedex 20, France</aff></contrib-group>
<author-notes>
<corresp id="c1-ijms-11-00206">
<label>⋆</label> Author to whom correspondence should be addressed; E-Mail: 
<email>jerome.wenger@fresnel.fr</email>; Tel.: +33-491-288-494.</corresp></author-notes>
<pub-date pub-type="epub">
<day>13</day>
<month>1</month>
<year>2010</year></pub-date>
<pub-date pub-type="collection">
<month>1</month>
<year>2010</year></pub-date>
<volume>11</volume>
<issue>1</issue>
<fpage>206</fpage>
<lpage>221</lpage>
<history>
<date date-type="received">
<day>24</day>
<month>11</month>
<year>2009</year></date>
<date date-type="rev-recd">
<day>4</day>
<month>1</month>
<year>2010</year></date>
<date date-type="accepted">
<day>8</day>
<month>1</month>
<year>2010</year></date></history>
<permissions>
<copyright-statement>© 2010 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland.</copyright-statement>
<copyright-year>2010</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/3.0">
<p>This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).</p></license></permissions>
<abstract>
<p>Recent advances in nanophotonics open the way for promising applications towards efficient single molecule fluorescence analysis. In this review, we discuss how photonic methods bring innovative solutions for two essential questions: how to detect a single molecule in a highly concentrated solution, and how to enhance the faint optical signal emitted per molecule? The focus is set primarily on the widely used technique of fluorescence correlation spectroscopy (FCS), yet the discussion can be extended to other single molecule detection methods.</p></abstract>
<kwd-group>
<kwd>single molecule</kwd>
<kwd>fluorescence correlation spectroscopy FCS</kwd>
<kwd>nanophotonics</kwd>
<kwd>biophotonics</kwd></kwd-group></article-meta></front>
<body>
<sec sec-type="intro">
<label>1.</label>
<title>Introduction</title>
<p>The capacity to detect and analyze optical signals emitted from single molecules is a key issue in nanosciences, especially for biological applications. Data from a single molecule may reveal information hidden by ensemble measurements, such as variances in kinetic rates, memory effects, or transient states [<xref ref-type="bibr" rid="b1-ijms-11-00206">1</xref>]. Observing a single or few dye molecules enables the study of dynamics and characteristics of the sample without actually disturbing their equilibrium. Therefore, efficiently detecting a single molecule has become a major goal with applications in chemical, biochemical and biophysical analysis.</p>
<p>Among the large number of methods that have been developed to investigate single molecules [<xref ref-type="bibr" rid="b2-ijms-11-00206">2</xref>], fluorescence spectroscopy plays the largest role today. Fluorescence bears a high intrinsic optical efficiency, and provides information about the molecular environment and structure in many different ways: brightness, lifetime, anisotropy or spectrum.</p>
<p>To analyse the fluorescence signal from a single molecule, fluorescence correlation spectroscopy (FCS) is a powerful and versatile method [<xref ref-type="bibr" rid="b3-ijms-11-00206">3</xref>, <xref ref-type="bibr" rid="b4-ijms-11-00206">4</xref>]. FCS is based on the statistical analysis of the temporal fluctuations affecting the fluorescence intensity. It can in principle provide information about any molecular process that induces a change in the fluorescence intensity. For instance, fluctuations occur when molecules diffuse in and out of an observation volume, or when reaction kinetics or conformational changes induce a change in the fluorescence brightness. Applications include determining translational and rotational diffusion, molecular concentrations, chemical kinetics, and binding reactions [<xref ref-type="bibr" rid="b5-ijms-11-00206">5</xref>].</p>
<p>A critical issue in FCS as in any single molecule experiment is to discriminate the (weak) relevant signal from the noise, which requires simultaneously high fluorescence count rates per molecule and low background. Therefore, FCS is commonly implemented on a confocal microscope with a high-end immersion objective, providing high resolution and large numerical aperture (see <xref ref-type="fig" rid="f1-ijms-11-00206">Figure 1</xref>). Despite its extreme sensitivity, this approach remains limited by the phenomenon of optical diffraction.</p>
<p>Optical diffraction limits confocal microscopy in two ways. First, it restricts the analysis volume to rather large values of typically 0.5 femtoliter (= 0.5 <italic>μ</italic>m<sup>3</sup>). This amounts to a useful concentration in the nanomolar range in order to isolate only a few molecules, which comes in contradiction to the concentrations in the micro to the millimolar range typically found in living cells. Second, optical diffraction restricts confocal microscopy to relatively low detection rates per molecule. This limits the choice of fluorescence markers to relatively bright species, and imposes long integration times.</p>
<p>Recent advances in nanophotonics and fluorescence microscopy offer new solutions to overcome the limits imposed by diffraction [<xref ref-type="bibr" rid="b6-ijms-11-00206">6</xref>–<xref ref-type="bibr" rid="b8-ijms-11-00206">8</xref>]. Drawing a parallel with computer engineering (<xref ref-type="fig" rid="f2-ijms-11-00206">Figure 2</xref>), nanosciences enable major breakthroughs in designing novel photonic tools for single molecule analysis. The observation volume can be reduced by several orders of magnitude below the diffraction-limited confocal volume, while the detected fluorescence rate per molecule can be enhanced more than ten times. The photonic environment can affect the fluorescence emission in three ways: (i) by locally enhancing the excitation intensity, (ii) by increasing the emitter’s radiative rate and quantum efficiency, and (iii) by modifying its radiation pattern, towards a higher emission directionality to the detectors. A major goal is to tailor the electromagnetic environment surrounding the molecules, so as to simultaneously enhance the collected fluorescence and decrease the detection volume to reduce background noise and enlarge the practicable domain of concentrations for single-molecule analysis.</p>
<p>In this contribution, we focus on two fundamental questions that bear highly practical applications: how to detect one single molecule in a highly concentrated solution, and how to enhance the faint optical signal emitted per molecule? Both key parameters of volume reduction and fluorescence rate enhancement will be discussed. The focus is set primarily on the widely used technique of fluorescence correlation spectroscopy (FCS), yet the discussion can be extended to other single molecule detection methods. We divide the different strategies into two main areas. The first one takes advantages of shaping the laser excitation beam in an unconventional manner (Section 2), while the second introduces photonic structures to overcome the diffraction limit (Section 3).</p></sec>
<sec>
<label>2.</label>
<title>Improved Single Molecule Fluorescence Detection by Structuring the Laser Excitation Beam</title>
<p>To improve single molecule fluorescence detection, several optical methods have been suggested and tested in light microscopy. The methods regrouped in this section share the fact that they primarily focus on modifying the laser excitation beam to further confine light on the nanoscale and improve the spatial resolution. <xref ref-type="fig" rid="f3-ijms-11-00206">Figure 3</xref> describes the different methods of this section, the line at the bottom of each picture summarizes the main physical concept used.</p>
<sec>
<label>2.1.</label>
<title>Total Internal Reflection Fluorescence Microscopy: TIRF</title>
<p>This system takes advantage of a total internal reflection fluorescence (TIRF) microscopy setup. Fluorescent molecules diffusing above the upper interface of the TIRF prism or objective are excited by an evanescent wave generated by total internal reflection at the solid/liquid interface [<xref ref-type="bibr" rid="b9-ijms-11-00206">9</xref>]. The shallow evanescent field in the liquid elegantly defines an analysis volume that is strongly reduced along the longitudinal direction. Its longitudinal extend typically amounts to ~ λ/6, which offers a reduction of 10 compared to conventional confocal microscopes. An important feature for this technique is that still a confocal pinhole conjugated to the object plane has to be used in order to reduce the lateral dimensions of the fluorescence analysis volume [<xref ref-type="bibr" rid="b10-ijms-11-00206">10</xref>]. TIRF-FCS offers an excellent axial confinement, yet it does not provide lateral confinement of the excitation profile and a pinhole in the image plane is needed to reduce the lateral extension of the detection profile. Therefore, out-of-focus photobleaching can be a major issue in TIRF-FCS, leading to a depletion of fluorophores and limiting the accuracy of FCS measurements.</p>
<p>Originally introduced in 1981 [<xref ref-type="bibr" rid="b9-ijms-11-00206">9</xref>], this technique can now be combined with commercially available microscope objectives for TIRF imaging [<xref ref-type="bibr" rid="b10-ijms-11-00206">10</xref>]. This tool can be used as efficiently for analyzing molecules diffusion in solution or in a lipid membrane [<xref ref-type="bibr" rid="b11-ijms-11-00206">11</xref>], and is also compatible with multi-dye fluorescence detection [<xref ref-type="bibr" rid="b13-ijms-11-00206">13</xref>].</p>
<p>Lastly, it can be combined with a thin metal layer for specific excitation of surface plasmon modes, which offers further background noise reduction and longitudinal confinement [<xref ref-type="bibr" rid="b12-ijms-11-00206">12</xref>].</p></sec>
<sec>
<label>2.2.</label>
<title>Fluorescence Detection on a Mirror</title>
<p>Single molecule detection in solution is tightly bound to the implementation of confocal microscopy, as depicted on <xref ref-type="fig" rid="f1-ijms-11-00206">Figure 1</xref>. An elegant way to reduce the confocal analysis volume and enhance the fluorescence rate emitted per molecule takes advantage of a dielectric mirror set at the focal point of the excitation beam (see <xref ref-type="fig" rid="f3-ijms-11-00206">Figure 3</xref>). The mirror affects both the laser excitation intensity and pattern, and the collection of the emitted fluorescence. The coherent excitation beam, which is reflected, produces an interference pattern along the optical axis with an interfringe spacing of λ/2<italic>n</italic>, where λ is the excitation wavelength and <italic>n</italic> is the medium refractive index.</p>
<p>Two important effects occur when the confocal detection volume is located on the mirrors surface [<xref ref-type="bibr" rid="b14-ijms-11-00206">14</xref>, <xref ref-type="bibr" rid="b15-ijms-11-00206">15</xref>]. First, interference fringes in the excitation beam give rise to a new characteristic time in the fluorescence correlation function. This new time is found to be independent of the transverse excitation fields beam waist and permits accurate measurement of diffusion coefficients without any a priori knowledge of the confocal volume geometry. Second, the count rate per emitter is significantly enhanced owing to control of spontaneous emission and enhancement of the excitation field, with a gain up to four times.</p>
<p>This technique has been applied to accurately measure the diffusion coefficient of the enhanced green fluorescent protein (EGFP) in the cytoplasm of living <italic>Escherichia coli</italic> [<xref ref-type="bibr" rid="b16-ijms-11-00206">16</xref>].</p></sec>
<sec>
<label>2.3.</label>
<title>4Pi Microscopy</title>
<p>New light microscopy concepts have been developed to improve the spatial resolution up to about 20 nm [<xref ref-type="bibr" rid="b17-ijms-11-00206">17</xref>]. Among them, 4Pi microscopy takes advantage of two opposite microscope objectives with high numerical apertures [<xref ref-type="bibr" rid="b18-ijms-11-00206">18</xref>]. Its principle is illustrated in <xref ref-type="fig" rid="f3-ijms-11-00206">Figure 3</xref>. Coherent light from a laser is split into two beams, which are focused at the same point onto a sample by two opposite objectives. Constructive interference of the two beams enhances the focusing of the light, and the illuminated region is narrower along the optical axis than in the case of the common confocal microscope. In 4Pi microscopy, various types of illumination and detection are utilized: type A corresponds to the illumination via two objectives with constructive interference and detection through one of the objectives in a confocal mode (commercially available); in type C, both illumination and detection are performed using two objectives, with constructive interference in both cases.</p>
<p>Increasing the number of objectives to two (or more) decreases the detection volume and increases the fluorescence collection efficiency. The 4Pi microscope features a point spread function with a central peak of 100 nm width in the axial direction and 220 nm width in the focal plane. In addition, the point spread function has smaller secondary maxima spaced on the optical axis at a distance of about half a wavelength from the main maximum. The essential point is that about 90% of the fluorescence signal stems from the main peak. Thus, the observation volume is virtually coincident with that of the main maximum of the point spread function.</p>
<p>A major problem in the adaptation of 4Pi microscopy to FCS is to account for the complicated point spread function of the microscope. A theoretical and computational framework has therefore been developed for data analysis, and validated by measurements on model systems [<xref ref-type="bibr" rid="b19-ijms-11-00206">19</xref>].</p></sec>
<sec>
<label>2.4.</label>
<title>Stimulated Emission Depletion Microscopy: STED</title>
<p>A different approach to overcome the diffraction barrier is to use stimulated emission depletion (STED) of the fluorescent molecular state (<xref ref-type="fig" rid="f3-ijms-11-00206">Figure 3</xref>) [<xref ref-type="bibr" rid="b17-ijms-11-00206">17</xref>]. STED is a far-field method bearing sub-diffraction analysis volumes suitable for FCS. In STED, a regular diffraction-limited focal spot (green) is used to excite the fluorescence, while a second laser beam (red) stimulates the excited molecules down to their ground state. The laser beam for stimulated emission is custom-tailored to feature a zero-intensity minimum at the center but high intensity in the focal periphery. This configuration ensures that fluorescence occurs only in the very center of the focal spots and is strongly suppressed in the spots periphery. An additional attractive feature of STED is that it allows to adjust the detection volume by increasing the power of the stimulating beam.</p>
<p>The first implementation of a STED experiment with FCS was published by Kastrup <italic>et al.</italic> [<xref ref-type="bibr" rid="b20-ijms-11-00206">20</xref>]. In a series of FCS measurements on a dilute solution of a red-fluorescing oxazine dye, the STED irradiance was successively increased yielding a 25-fold reduction of the axial diffusion time, equivalent to a 5-fold reduction of the focal volume. However, much stronger analysis volume reduction can be expected with that method.</p>
<p>In a second contribution, STED-FCS was used to investigate the cell membrane architecture at the nanoscale [<xref ref-type="bibr" rid="b21-ijms-11-00206">21</xref>]. Single diffusing lipid molecules were detected in nanosized areas in the plasma membrane of living cells. Tuning of the probed area 70-fold below the diffraction barrier reveals that sphingolipids and glycosylphosphatidylinositol-anchored proteins are transiently trapped in cholesterol-mediated molecular complexes dwelling within 20 nm diameter areas. This tunable noninvasive optical recording combined to nanoscale imaging is a powerful new approach to study the dynamics of molecules in living cells.</p></sec></sec>
<sec>
<label>3.</label>
<title>Improved Single Molecule Fluorescence Detection by Using Photonic Structures</title>
<p>Optical methods of this section introduce photonic structures from millimeter to nanometer size to improve the detection of the fluorescence signal. The first two techniques (paraboloid collector and solid immersion lens) make the transition with the methods discussed in Section 2 and introduce many key concepts of nanophotonics. The last four techniques go really into the nanoworld of photonics. In addition to <xref ref-type="fig" rid="f3-ijms-11-00206">Figure 3</xref>, <xref ref-type="fig" rid="f4-ijms-11-00206">Figure 4</xref> describes the photonic methods of this section for enhanced detection.</p>
<sec>
<label>3.1.</label>
<title>Paraboloid Collector</title>
<p>This main core of this technique is to replace the microscope objective by a paraboloid glass segment acting as a mirror for collecting the fluorescence (<xref ref-type="fig" rid="f4-ijms-11-00206">Figure 4</xref>). A special feature of the system is its ability to sample not only fluorescence that is emitted below the angle of total internal reflection (known as the critical angle) but also particularly the light above the critical angle. This is especially advantageous for collecting the fluorescence of surface-bound molecules. This specific optical system leads to a fluorescence collection efficiency to more than 65% of the total of emitted light, whereas high numerical aperture microscope objectives are able to collect 44% at best. Moreover, the detection volume can be restricted ten times below the standard confocal volume [<xref ref-type="bibr" rid="b22-ijms-11-00206">22</xref>, <xref ref-type="bibr" rid="b23-ijms-11-00206">23</xref>]. This allows for a strong discrimination of bulk-generated against surface-generated fluorescence, which may be of great value when surface-binding processes are monitored.</p>
<p>The potential of a paraboloid collector (also referred to as supercritical angle objective) for FCS has been discussed in [<xref ref-type="bibr" rid="b24-ijms-11-00206">24</xref>], demonstrating a clear advantage of paraboloid-FCS for diffusion measurements in lipid membranes. This method circumvents the need to illuminate at large angles as with TIRF and achieves an excellent axial confinement in combination with a small lateral excitation spot of a customized confocal microscope.</p></sec>
<sec>
<label>3.2.</label>
<title>Solid Immersion Lens: SIL</title>
<p>For FCS, confinement of the excitation field and high fluorescence collection efficiency are key parameters. Both are directly proportional to the numerical aperture (NA) of the microscope objective system. Immersing the analysis volume with a liquid of a high refractive index, e.g., oil, increases the effective NA. Another way to increase the NA can be achieved by utilizing a solid immersion lens or SIL (<xref ref-type="fig" rid="f4-ijms-11-00206">Figure 4</xref>). A SIL is generally a hemisphere made in a material of high refractive index that is set at the focus of a microscope objective to further increase the overall NA of the whole system [<xref ref-type="bibr" rid="b25-ijms-11-00206">25</xref>].</p>
<p>To perform FCS at high molecular concentrations with an ultra-high NA, an option is to combine a 0.6 NA air objective to a solid immersion lens (SIL) with refractive index close to 2 [<xref ref-type="bibr" rid="b26-ijms-11-00206">26</xref>]. Experiments performed on a commercial FCS apparatus (Zeiss ConfoCorr 1) shown 50% higher collection efficiency and better field confinement for the SIL system in comparison to the conventional confocal set-up. Performances can be increased further by aberration compensation and pre-shaping the incident wavefront to obtain near diffraction-limited performance [<xref ref-type="bibr" rid="b27-ijms-11-00206">27</xref>].</p></sec>
<sec>
<label>3.3.</label>
<title>Microspheres</title>
<p>Dielectric microspheres can be a viable alternative for enhanced fluorescence detection in solution, offering a simple and low-cost method [<xref ref-type="bibr" rid="b28-ijms-11-00206">28</xref>]. When a latex microsphere is illuminated with a tightly-focused Gaussian beam, it over-focuses light in a region with subwavelength dimensions in both the transverse and longitudinal directions, creating high local intensities. This effect stems from interferences between the field scattered by the sphere and the high angular components of the incident Gaussian beam passing aside the sphere [<xref ref-type="bibr" rid="b29-ijms-11-00206">29</xref>].</p>
<p>Latex microspheres have been exploited to enhance the detection of single fluorescent molecules in FCS, yielding a simultaneous decrease of the confocal observation volume by an order of magnitude and an enhancement of the fluorescence brightness by a factor of five [<xref ref-type="bibr" rid="b28-ijms-11-00206">28</xref>]. This phenomenon was explained as the microsphere increases the excitation intensity sensed by the molecule up to a factor of 2.2, while at the same time it allows for a gain in collection efficiency up to 60% by redirecting the light emitted at large incidences towards the optical axis [<xref ref-type="bibr" rid="b30-ijms-11-00206">30</xref>]. Commercially available latex microspheres therefore appear as an attractive and cost-effective route to enhance the confocal microscopes for FCS without requiring expensive nanofabrication facilities.</p>
<p>Latex microspheres can also be combined with a simple low NA lens to form a high performance disposable optical system. This offers a simple and low-cost alternative to the expensive microscope objectives used in FCS [<xref ref-type="bibr" rid="b31-ijms-11-00206">31</xref>]. Moreover, microspheres can be combined to an optical fiber for remote FCS analysis in an endoscopic apparatus [<xref ref-type="bibr" rid="b32-ijms-11-00206">32</xref>]. The technique is sensitive enough to detect single fluorescent molecules. This offers new opportunities for reducing the bulky microscope setup and extending FCS to remote or in vivo applications.</p></sec>
<sec>
<label>3.4.</label>
<title>Nanofluidic Channels</title>
<p>Novel nanofabrication techniques enable the realization of structures to confine the sampling volume in the fluorescent solution on sizes much smaller than the diffraction limit. Mechanically restricting the observation volume directly improves the efficiency of FCS toward micromolar concentration ranges [<xref ref-type="bibr" rid="b33-ijms-11-00206">33</xref>]. It also simultaneously improves slightly the fluorescence rate per molecule by detecting only the molecules that sense the strongest excitation intensity at the center of the laser spot.</p>
<p>Foquet and coworkers have used nanofabricated channels with dimensions smaller or equal to the width and depth of a diffraction-limited detection volume in confocal microscopy for FCS studies [<xref ref-type="bibr" rid="b34-ijms-11-00206">34</xref>, <xref ref-type="bibr" rid="b35-ijms-11-00206">35</xref>]. An effective detection volume of few tens of attoliters was achieved (see <xref ref-type="fig" rid="f4-ijms-11-00206">Figure 4</xref>). The nanochannels had typical dimensions of a few hundred nanometers in their cross-section. Such nanometer sized channels offer natural platforms for optofluidic sensing devices to achieve high-throughput analysis systems at the single molecule level. Furthermore, FCS can be applied successfully to measure velocities and directionalities in different capillaries for hydrodynamic and electrophoretic flows [<xref ref-type="bibr" rid="b36-ijms-11-00206">36</xref>].</p>
<p>Lastly, nanochannels open new opportunities for full implementation of FCS on a chip [<xref ref-type="bibr" rid="b37-ijms-11-00206">37</xref>]. Full planar integration can be achieved by lithographic definition of sub-picoliter excitation volumes using intersecting solid and liquid-core optical waveguides. Silicon micro and nanophotonics are thus to replace free-space microscopes, and offer even higher performances. This permits implementation of numerous diagnostic applications on compact planar optofluidic devices.</p></sec>
<sec>
<label>3.5.</label>
<title>Near-Field Scanning Optical Microscope: NSOM</title>
<p>Near-field scanning optical microscopy (NSOM) is based on a subwavelength-sized light source that is raster-scanned across a surface at a distance of a few nanometers to image the sample. Near-field optical methods have been widely developed to provide spatial resolutions of 10?30 nm [<xref ref-type="bibr" rid="b38-ijms-11-00206">38</xref>]. Compared to the other systems described in this section, NSOM bears the essential ability to image the sample.</p>
<p>NSOM microscopes are typically implemented using tapered optical single-mode fibers that are coated with a thin layer of aluminum. At the apex of the tip, an aperture of nanometer size is opened by focused ion beam milling (<xref ref-type="fig" rid="f4-ijms-11-00206">Figure 4</xref>). The region illuminated at the apex of the tip is constrained both in the lateral and longitudinal directions (for an aperture diameter typically below half the wavelength, the laser field evanescently decays inside the aperture, with a longitudinal extend of about 100 nm).</p>
<p>FCS measurements using NSOM probes have been reported in [<xref ref-type="bibr" rid="b39-ijms-11-00206">39</xref>]. An order of magnitude reduction in the area compared to confocal FCS has been achieved, while the use of probes with smaller apertures is expected to provide an additional order of magnitude reduction. It was also reported that bare chemically etched, tapered fiber tips could be implemented for NSOM-FCS [<xref ref-type="bibr" rid="b40-ijms-11-00206">40</xref>].</p>
<p>Very recently, NSOM-FCS was applied to study proteins diffusion passing through individual nuclear pore complexes of the nuclear envelope [<xref ref-type="bibr" rid="b41-ijms-11-00206">41</xref>]. FCS characterizes the translocation as driven by Brownian motion and determines the related kinetic constants.</p></sec>
<sec>
<label>3.6.</label>
<title>Nanometric Apertures</title>
<p>A simple and elegant way of generating a reduced analysis volume for FCS implements a single nanometric aperture milled in an opaque metallic film. As illustrated on <xref ref-type="fig" rid="f4-ijms-11-00206">Figure 4</xref>, the nanoaperture acts as a pinhole filter located directly into the object plane. When the aperture diameter is sufficiently reduced below the cut-off diameter of the fundamental excitation mode that may propagate through the aperture, the light inside the aperture is confined to a rapidly decaying evanescent mode, with a decay length of a few tens of nanometers (such devices have thus been named zero-mode waveguides). This concepts bears strong relations with NSOM probes, yet in a much more robust and easy to use configuration. Since both excitation and fluorescence collection are performed from the glass substrate side, very high detection efficiencies can be reached.</p>
<p>An impressive amount of literature has been published about the use of nanoapertures for FCS, since the pioneering demonstration of Levene and coworkers in 2003 [<xref ref-type="bibr" rid="b42-ijms-11-00206">42</xref>]. With aperture diameters down to 30 nm, detection volumes of a few tens of zeptoliters (1 zL = 10<sup>21</sup> L) have been generated, which are about four orders of magnitude smaller than diffraction-limited confocal volumes. DNA polymerase activity can be monitored at the single molecule level at dye concentrations of a few tens of micromolar. Implementation of nanoapertures currently provides the best performances for FCS at high concentrations [<xref ref-type="bibr" rid="b43-ijms-11-00206">43</xref>, <xref ref-type="bibr" rid="b44-ijms-11-00206">44</xref>]. The applications can be extended to dual-color cross-correlation FCCS analysis [<xref ref-type="bibr" rid="b45-ijms-11-00206">45</xref>], and to monitor flow mixing [<xref ref-type="bibr" rid="b46-ijms-11-00206">46</xref>].</p>
<p>A second major effect brought by the sub-wavelength aperture is that it can significantly enhance the detected fluorescence rate per emitter. Using single rhodamine 6G molecules in isolated 150 nm diameter apertures milled in an aluminum film, a 6.5 fold enhancement of the fluorescence rate per molecule was reported as compared to free solution [<xref ref-type="bibr" rid="b47-ijms-11-00206">47</xref>, <xref ref-type="bibr" rid="b48-ijms-11-00206">48</xref>]. Further enhancement up to 25-fold can be obtained by tuning the plasmon properties of the nanoapertures [<xref ref-type="bibr" rid="b49-ijms-11-00206">49</xref>–<xref ref-type="bibr" rid="b51-ijms-11-00206">51</xref>]. This provides a dramatic increase in signal-to-noise ratio (SNR) for FCS even at single molecule resolution. An experimental gain in SNR of about 1 order of magnitude, corresponds to a 100-fold reduction of the experiment duration, evidencing the feasibility of FCS analysis with fast integration times of about 1 s [<xref ref-type="bibr" rid="b52-ijms-11-00206">52</xref>]. This opens the way to monitoring of a variety of biochemical reactions at reduced time scales.</p>
<p>Biophotonic applications of nanoapertures are reviewed for instance in [<xref ref-type="bibr" rid="b53-ijms-11-00206">53</xref>]. The illuminated area well below the diffraction limit has proven of essential interest for FCS studies in lipid bilayers [<xref ref-type="bibr" rid="b54-ijms-11-00206">54</xref>, <xref ref-type="bibr" rid="b55-ijms-11-00206">55</xref>] as well as in live cell membranes [<xref ref-type="bibr" rid="b56-ijms-11-00206">56</xref>–<xref ref-type="bibr" rid="b58-ijms-11-00206">58</xref>]. Nanoapertures combined to FCS offer the advantages of both high spatial and temporal resolution together with a direct statistical analysis.</p>
<p>Lastly, a very promising application of nanometric apertures concerns real-time single-molecule DNA sequencing [<xref ref-type="bibr" rid="b59-ijms-11-00206">59</xref>]. Performing high-throughput, high-accuracy DNA sequencing at low costs has become a major issue, largely attracted by the growing potential of quantitative genomics. Each nanoaperture forms a nano-observation chamber for watching the activity of a single DNA polymerase enzyme performing DNA sequencing by synthesis.</p></sec></sec>
<sec sec-type="conclusions">
<label>4.</label>
<title>Conclusions</title>
<p>At least ten different strategies have been demonstrated to enhance single molecule detection techniques beyond the limits set by optical diffraction. <xref ref-type="table" rid="t1-ijms-11-00206">Table 1</xref> summarizes their respective properties for reducing the analysis volume and enhancing the detected fluorescence rate per molecule. This enables fast comparison between the techniques and standard confocal microscopy. <xref ref-type="table" rid="t1-ijms-11-00206">Table 1</xref> also provides our arbitrary vision of the respective complexity required while setting up these novel strategies. Lastly, <xref ref-type="fig" rid="f5-ijms-11-00206">Figure 5</xref> illustrates the practical ranges of concentrations offered by each method for single molecule detection.</p>
<p>Based on the end-user application requirements, we believe that many photonic strategies exist to enhance single molecule fluorescence detection. For those needing simple and robust integration with commercially available systems, TIRF microscope objectives, paraboloid objectives and polystyrene microspheres offer relevant improvements. For maximum integration into optofluidic systems, nanochannels possibly equipped with microspheres or nanoapertures are the natural choice. Lastly, for maximum performance, nanoapertures offer the best gains, both in volume reduction and fluorescence rate enhancement.</p></sec></body>
<back>
<ack>
<p>The authors acknowledge stimulating discussions with S. Blair, N. Bonod, T.W. Ebbesen, D. Gérard, E. Popov and H. Aouani. This work has been funded by the French Agence Nationale de la Recherche under contract ANR-07-NANO-006-03 “ANTARES”.</p></ack>
<ref-list>
<title>References</title>
<ref id="b1-ijms-11-00206"><label>1.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Zander</surname><given-names>C</given-names></name><name><surname>Enderlein</surname><given-names>J</given-names></name><name><surname>Keller</surname><given-names>RA</given-names></name></person-group><source>Single-Molecule Detection in Solution—Methods and Applications</source><publisher-name>VCH-Wiley</publisher-name><publisher-loc>Berlin, Germany</publisher-loc><year>2002</year></citation></ref>
<ref id="b2-ijms-11-00206"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Craighead</surname><given-names>HG</given-names></name></person-group><article-title>Future lab-on-a-chip technologies for interrogating individual molecules</article-title><source>Nature</source><year>2006</year><volume>442</volume><fpage>387</fpage><lpage>393</lpage><pub-id pub-id-type="doi">10.1038/nature05061</pub-id><pub-id pub-id-type="pmid">16871206</pub-id></citation></ref>
<ref id="b3-ijms-11-00206"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Maiti</surname><given-names>S</given-names></name><name><surname>Haupts</surname><given-names>U</given-names></name><name><surname>Webb</surname><given-names>WW</given-names></name></person-group><article-title>Fluorescence correlation spectroscopy: diagnostics for sparse molecules</article-title><source>Proc. Nat. Acad. Sci. USA</source><year>1997</year><volume>94</volume><fpage>11753</fpage><lpage>11757</lpage><pub-id pub-id-type="doi">10.1073/pnas.94.22.11753</pub-id><pub-id pub-id-type="pmid">9342306</pub-id></citation></ref>
<ref id="b4-ijms-11-00206"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Webb</surname><given-names>WW</given-names></name></person-group><article-title>Fluorescence correlation spectroscopy: Inception, biophysical experimentations, and prospectus</article-title><source>Appl. Opt</source><year>2001</year><volume>40</volume><fpage>3969</fpage><lpage>3983</lpage><pub-id pub-id-type="doi">10.1364/AO.40.003969</pub-id><pub-id pub-id-type="pmid">18360431</pub-id></citation></ref>
<ref id="b5-ijms-11-00206"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Briddon</surname><given-names>SJ</given-names></name><name><surname>Hill</surname><given-names>SJ</given-names></name></person-group><article-title>Pharmacology under the microscope: The use of fluorescence correlation spectroscopy to determine the properties of ligandreceptor complexes</article-title><source>Trends Pharmacol. Sci</source><year>2007</year><volume>28</volume><fpage>637</fpage><lpage>645</lpage><pub-id pub-id-type="doi">10.1016/j.tips.2007.09.008</pub-id><pub-id pub-id-type="pmid">18001848</pub-id></citation></ref>
<ref id="b6-ijms-11-00206"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huser</surname><given-names>T</given-names></name></person-group><article-title>Nano-Biophotonics: New tools for chemical nano-analytics</article-title><source>Curr. Opin. Chem. Biol</source><year>2008</year><volume>12</volume><fpage>497</fpage><lpage>504</lpage><pub-id pub-id-type="doi">10.1016/j.cbpa.2008.08.012</pub-id><pub-id pub-id-type="pmid">18786651</pub-id></citation></ref>
<ref id="b7-ijms-11-00206"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Blom</surname><given-names>H</given-names></name><name><surname>Kastrup</surname><given-names>L</given-names></name><name><surname>Eggeling</surname><given-names>C</given-names></name></person-group><article-title>Fluorescence fluctuation spectroscopy in reduced detection Volumes</article-title><source>Curr. Pharm. Biotechnol</source><year>2006</year><volume>7</volume><fpage>51</fpage><lpage>66</lpage><pub-id pub-id-type="doi">10.2174/138920106775789629</pub-id><pub-id pub-id-type="pmid">16472133</pub-id></citation></ref>
<ref id="b8-ijms-11-00206"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mannion</surname><given-names>JT</given-names></name><name><surname>Craighead</surname><given-names>HG</given-names></name></person-group><article-title>Nanofluidic structures for single biomolecule fluorescent detection</article-title><source>Biopolymers</source><year>2006</year><volume>85</volume><fpage>131</fpage><lpage>143</lpage></citation></ref>
<ref id="b9-ijms-11-00206"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thompson</surname><given-names>NL</given-names></name><name><surname>Burghardt</surname><given-names>TP</given-names></name><name><surname>Axelrod</surname><given-names>D</given-names></name></person-group><article-title>Measuring surface dynamics of biomolecules by total internal–Reflection fluorescence with photobleaching recovery or correlation spectroscopy</article-title><source>Biophys. J</source><year>1981</year><volume>33</volume><fpage>435</fpage><lpage>454</lpage><pub-id pub-id-type="doi">10.1016/S0006-3495(81)84905-3</pub-id><pub-id pub-id-type="pmid">7225515</pub-id></citation></ref>
<ref id="b10-ijms-11-00206"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hassler</surname><given-names>K</given-names></name><name><surname>Leutenegger</surname><given-names>M</given-names></name><name><surname>Rigler</surname><given-names>P</given-names></name><name><surname>Rao</surname><given-names>R</given-names></name><name><surname>Rigler</surname><given-names>R</given-names></name><name><surname>Gösch</surname><given-names>M</given-names></name><name><surname>Lasser</surname><given-names>T</given-names></name></person-group><article-title>Total internal reflection fluorescence correlation spectroscopy (TIR-FCS) with low background and high count-rate per molecule</article-title><source>Opt. Express</source><year>2005</year><volume>13</volume><fpage>7415</fpage><lpage>7423</lpage><pub-id pub-id-type="doi">10.1364/OPEX.13.007415</pub-id><pub-id pub-id-type="pmid">19498766</pub-id></citation></ref>
<ref id="b11-ijms-11-00206"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Starr</surname><given-names>TE</given-names></name><name><surname>Thompson</surname><given-names>NL</given-names></name></person-group><article-title>Total internal reflection with fluorescence correlation spectroscopy: Combined surface reaction and solution diffusion</article-title><source>Biophys. J</source><year>2001</year><volume>80</volume><fpage>1575</fpage><lpage>1584</lpage><pub-id pub-id-type="doi">10.1016/S0006-3495(01)76130-9</pub-id><pub-id pub-id-type="pmid">11222318</pub-id></citation></ref>
<ref id="b12-ijms-11-00206"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Borejdo</surname><given-names>J</given-names></name><name><surname>Calander</surname><given-names>N</given-names></name><name><surname>Gryczynski</surname><given-names>Z</given-names></name><name><surname>Gryczynski</surname><given-names>I</given-names></name></person-group><article-title>Fluorescence correlation spectroscopy in surface plasmon coupled emission microscope</article-title><source>Opt. Express</source><year>2006</year><volume>14</volume><fpage>7878</fpage><lpage>7888</lpage><pub-id pub-id-type="doi">10.1364/OE.14.007878</pub-id><pub-id pub-id-type="pmid">19529155</pub-id></citation></ref>
<ref id="b13-ijms-11-00206"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Leutenegger</surname><given-names>M</given-names></name><name><surname>Blom</surname><given-names>H</given-names></name><name><surname>Widengren</surname><given-names>J</given-names></name><name><surname>Eggeling</surname><given-names>C</given-names></name><name><surname>Gösch</surname><given-names>M</given-names></name><name><surname>Leitgeb</surname><given-names>RA</given-names></name><name><surname>Lasser</surname><given-names>T</given-names></name></person-group><article-title>Dual-color total internal reflection fluorescence cross-correlation spectroscopy</article-title><source>J Biomed Optics</source><year>2006</year><volume>11</volume><fpage>040502</fpage>doi:10.1117/1.2221714<pub-id pub-id-type="doi">10.1117/1.2221714</pub-id></citation></ref>
<ref id="b14-ijms-11-00206"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lenne</surname><given-names>PF</given-names></name><name><surname>Etienne</surname><given-names>E</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name></person-group><article-title>Subwavelength patterns and high detection efficiency in fluorescence correlation spectroscopy using photonic structures</article-title><source>Appl. Phys. Lett</source><year>2002</year><volume>80</volume><fpage>4106</fpage><lpage>4108</lpage><pub-id pub-id-type="doi">10.1063/1.1483116</pub-id></citation></ref>
<ref id="b15-ijms-11-00206"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Lenne</surname><given-names>PF</given-names></name></person-group><article-title>Fluorescence correlation spectroscopy on a mirror</article-title><source>J. Opt. Soc. Am. B</source><year>2003</year><volume>20</volume><fpage>2203</fpage><lpage>2214</lpage><pub-id pub-id-type="doi">10.1364/JOSAB.20.002203</pub-id></citation></ref>
<ref id="b16-ijms-11-00206"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Etienne</surname><given-names>E</given-names></name><name><surname>Lenne</surname><given-names>PF</given-names></name><name><surname>Sturgis</surname><given-names>JN</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name></person-group><article-title>Confined diffusion in tubular structures analyzed by fluorescence correlation spectroscopy on a mirror</article-title><source>Appl. Opt</source><year>2006</year><volume>45</volume><fpage>4497</fpage><lpage>4507</lpage><pub-id pub-id-type="doi">10.1364/AO.45.004497</pub-id><pub-id pub-id-type="pmid">16778960</pub-id></citation></ref>
<ref id="b17-ijms-11-00206"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hell</surname><given-names>SW</given-names></name></person-group><article-title>Toward fluorescence nanoscopy</article-title><source>Nat. Biotechnol</source><year>2003</year><volume>21</volume><fpage>1347</fpage><lpage>1355</lpage><pub-id pub-id-type="doi">10.1038/nbt895</pub-id><pub-id pub-id-type="pmid">14595362</pub-id></citation></ref>
<ref id="b18-ijms-11-00206"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hell</surname><given-names>SW</given-names></name><name><surname>Stelzer</surname><given-names>EHK</given-names></name></person-group><article-title>Fundamental improvement of resolution with a 4Pi-confocal fluorescence microscope using twophoton excitation</article-title><source>Opt. Commun</source><year>1992</year><volume>93</volume><fpage>277</fpage><lpage>282</lpage><pub-id pub-id-type="doi">10.1016/0030-4018(92)90185-T</pub-id></citation></ref>
<ref id="b19-ijms-11-00206"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Arkhipov</surname><given-names>A</given-names></name><name><surname>Hüve</surname><given-names>J</given-names></name><name><surname>Kahms</surname><given-names>M</given-names></name><name><surname>Peters</surname><given-names>R</given-names></name><name><surname>Schulten</surname><given-names>K</given-names></name></person-group><article-title>Continuous fluorescence microphotolysis and correlation spectroscopy using 4Pi microscopy</article-title><source>Biophys. J</source><year>2007</year><volume>93</volume><fpage>4006</fpage><lpage>4017</lpage><pub-id pub-id-type="doi">10.1529/biophysj.107.107805</pub-id><pub-id pub-id-type="pmid">17704168</pub-id></citation></ref>
<ref id="b20-ijms-11-00206"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kastrup</surname><given-names>L</given-names></name><name><surname>Blom</surname><given-names>H</given-names></name><name><surname>Eggeling</surname><given-names>C</given-names></name><name><surname>Hell</surname><given-names>SW</given-names></name></person-group><article-title>Fluorescence fluctuation spectroscopy in subdiffraction focal volumes</article-title><source>Phys Rev Lett</source><year>2005</year><volume>94</volume><fpage>178104:1</fpage><lpage>178104:4</lpage></citation></ref>
<ref id="b21-ijms-11-00206"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Eggeling</surname><given-names>C</given-names></name><name><surname>Ringemann</surname><given-names>C</given-names></name><name><surname>Medda</surname><given-names>R</given-names></name><name><surname>Schwarzmann</surname><given-names>G</given-names></name><name><surname>Sandhoff</surname><given-names>K</given-names></name><name><surname>Polyakova</surname><given-names>S</given-names></name><name><surname>Belov</surname><given-names>VN</given-names></name><name><surname>Hein</surname><given-names>B</given-names></name><name><surname>von Middendorff</surname><given-names>C</given-names></name><name><surname>Schönle</surname><given-names>A</given-names></name><name><surname>Hell</surname><given-names>SW</given-names></name></person-group><article-title>Direct observation of the nanoscale dynamics of membrane lipids in a living cell</article-title><source>Nature</source><year>2008</year><volume>457</volume><fpage>1159</fpage><lpage>1162</lpage><pub-id pub-id-type="pmid">19098897</pub-id></citation></ref>
<ref id="b22-ijms-11-00206"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Enderlein</surname><given-names>J</given-names></name><name><surname>Ruckstuhl</surname><given-names>T</given-names></name><name><surname>Seeger</surname><given-names>S</given-names></name></person-group><article-title>Highly efficient optical detection of surface-generated fluorescence</article-title><source>Appl. Opt</source><year>1999</year><volume>38</volume><fpage>724</fpage><lpage>732</lpage><pub-id pub-id-type="doi">10.1364/AO.38.000724</pub-id><pub-id pub-id-type="pmid">18305670</pub-id></citation></ref>
<ref id="b23-ijms-11-00206"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ruckstuhl</surname><given-names>T</given-names></name><name><surname>Enderlein</surname><given-names>J</given-names></name><name><surname>Jung</surname><given-names>S</given-names></name><name><surname>Seeger</surname><given-names>S</given-names></name></person-group><article-title>Forbidden light detection from single molecules</article-title><source>Anal. Chem</source><year>2000</year><volume>72</volume><fpage>2117</fpage><lpage>2123</lpage><pub-id pub-id-type="doi">10.1021/ac991358k</pub-id><pub-id pub-id-type="pmid">10815974</pub-id></citation></ref>
<ref id="b24-ijms-11-00206"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ries</surname><given-names>J</given-names></name><name><surname>Ruckstuhl</surname><given-names>T</given-names></name><name><surname>Verdes</surname><given-names>D</given-names></name><name><surname>Schwille</surname><given-names>P</given-names></name></person-group><article-title>Supercritical angle fluorescence correlation spectroscopy</article-title><source>Biophys. J</source><year>2008</year><volume>94</volume><fpage>221</fpage><lpage>229</lpage><pub-id pub-id-type="doi">10.1529/biophysj.107.115998</pub-id><pub-id pub-id-type="pmid">17827221</pub-id></citation></ref>
<ref id="b25-ijms-11-00206"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Koyama</surname><given-names>K</given-names></name><name><surname>Yoshita</surname><given-names>M</given-names></name><name><surname>Baba</surname><given-names>M</given-names></name><name><surname>Suemoto</surname><given-names>T</given-names></name><name><surname>Akiyama</surname><given-names>H</given-names></name></person-group><article-title>High collection efficiency in fluorescence microscopy with a Solid Immersion Lens</article-title><source>Appl. Phys. Lett</source><year>1999</year><volume>75</volume><fpage>1667</fpage><lpage>1669</lpage><pub-id pub-id-type="doi">10.1063/1.124833</pub-id></citation></ref>
<ref id="b26-ijms-11-00206"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Serov</surname><given-names>A</given-names></name><name><surname>Rao</surname><given-names>R</given-names></name><name><surname>Gösch</surname><given-names>M</given-names></name><name><surname>Anhut</surname><given-names>T</given-names></name><name><surname>Martin</surname><given-names>D</given-names></name><name><surname>Brunner</surname><given-names>R</given-names></name><name><surname>Rigler</surname><given-names>R</given-names></name><name><surname>Lasser</surname><given-names>T</given-names></name></person-group><article-title>High light field confinement for fluorescent correlation spectroscopy using a solid immersion lens</article-title><source>Biosens. Bioelectron</source><year>2004</year><volume>20</volume><fpage>431</fpage><lpage>435</lpage><pub-id pub-id-type="doi">10.1016/j.bios.2004.02.028</pub-id><pub-id pub-id-type="pmid">15494221</pub-id></citation></ref>
<ref id="b27-ijms-11-00206"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rao</surname><given-names>R</given-names></name><name><surname>Mitic</surname><given-names>J</given-names></name><name><surname>Serov</surname><given-names>A</given-names></name><name><surname>Leitgeb</surname><given-names>RA</given-names></name><name><surname>Lasser</surname><given-names>T</given-names></name></person-group><article-title>Field confinement with aberration correction for solid immersion lens based fluorescence correlation spectroscopy</article-title><source>Opt. Commun</source><year>2007</year><volume>271</volume><fpage>462</fpage><lpage>469</lpage><pub-id pub-id-type="doi">10.1016/j.optcom.2006.10.044</pub-id></citation></ref>
<ref id="b28-ijms-11-00206"><label>28.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gérard</surname><given-names>D</given-names></name><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Devilez</surname><given-names>A</given-names></name><name><surname>Gachet</surname><given-names>D</given-names></name><name><surname>Stout</surname><given-names>B</given-names></name><name><surname>Bonod</surname><given-names>N</given-names></name><name><surname>Popov</surname><given-names>E</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name></person-group><article-title>Strong electromagnetic confinement near dielectric microspheres to enhance single-molecule fluorescence</article-title><source>Opt. Express</source><year>2008</year><volume>16</volume><fpage>15297</fpage><lpage>15303</lpage><pub-id pub-id-type="doi">10.1364/OE.16.015297</pub-id><pub-id pub-id-type="pmid">18795067</pub-id></citation></ref>
<ref id="b29-ijms-11-00206"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Devilez</surname><given-names>A</given-names></name><name><surname>Bonod</surname><given-names>N</given-names></name><name><surname>Stout</surname><given-names>B</given-names></name><name><surname>Gérard</surname><given-names>D</given-names></name><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Popov</surname><given-names>E</given-names></name></person-group><article-title>Three-dimensional subwavelength confinement of photonic nanojets</article-title><source>Opt. Express</source><year>2009</year><volume>17</volume><fpage>2089</fpage><lpage>2094</lpage><pub-id pub-id-type="doi">10.1364/OE.17.002089</pub-id><pub-id pub-id-type="pmid">19219113</pub-id></citation></ref>
<ref id="b30-ijms-11-00206"><label>30.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gérard</surname><given-names>D</given-names></name><name><surname>Devilez</surname><given-names>A</given-names></name><name><surname>Aouani</surname><given-names>H</given-names></name><name><surname>Stout</surname><given-names>B</given-names></name><name><surname>Bonod</surname><given-names>N</given-names></name><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Popov</surname><given-names>E</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name></person-group><article-title>Efficient excitation and collection of single molecule fluorescence close to a dielectric microsphere</article-title><source>J. Opt. Soc. Am. B</source><year>2009</year><volume>26</volume><fpage>1473</fpage><lpage>1478</lpage><pub-id pub-id-type="doi">10.1364/JOSAB.26.001473</pub-id></citation></ref>
<ref id="b31-ijms-11-00206"><label>31.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Gérard</surname><given-names>D</given-names></name><name><surname>Aouani</surname><given-names>H</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name></person-group><article-title>Disposable microscope objective lenses for fluorescence correlation spectroscopy using latex microspheres</article-title><source>Anal. Chem</source><year>2008</year><volume>80</volume><fpage>6800</fpage><lpage>6804</lpage><pub-id pub-id-type="doi">10.1021/ac801016z</pub-id><pub-id pub-id-type="pmid">18681458</pub-id></citation></ref>
<ref id="b32-ijms-11-00206"><label>32.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aouani</surname><given-names>H</given-names></name><name><surname>Deiss</surname><given-names>F</given-names></name><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Ferrand</surname><given-names>P</given-names></name><name><surname>Sojic</surname><given-names>N</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name></person-group><article-title>Optical-fiber-microsphere for remote fluorescence correlation spectroscopy</article-title><source>Opt. Express</source><year>2009</year><volume>17</volume><fpage>18912</fpage><lpage>18919</lpage></citation></ref>
<ref id="b33-ijms-11-00206"><label>33.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Brinkmeier</surname><given-names>M</given-names></name><name><surname>Dijrre</surname><given-names>K</given-names></name><name><surname>Riebeseel</surname><given-names>K</given-names></name><name><surname>Rigler</surname><given-names>R</given-names></name></person-group><article-title>Confocal spectroscopy in microstructures</article-title><source>Biophys. Chem</source><year>1997</year><volume>66</volume><fpage>229</fpage><lpage>239</lpage><pub-id pub-id-type="doi">10.1016/S0301-4622(97)00065-3</pub-id><pub-id pub-id-type="pmid">17029876</pub-id></citation></ref>
<ref id="b34-ijms-11-00206"><label>34.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Foquet</surname><given-names>M</given-names></name><name><surname>Korlach</surname><given-names>J</given-names></name><name><surname>Zipfel</surname><given-names>WR</given-names></name><name><surname>Webb</surname><given-names>WW</given-names></name><name><surname>Craighead</surname><given-names>HG</given-names></name></person-group><article-title>DNA fragment sizing by single molecule detection in submicrometer-sized closed fluidic channels</article-title><source>Anal. Chem</source><year>2002</year><volume>74</volume><fpage>1415</fpage><lpage>1422</lpage><pub-id pub-id-type="doi">10.1021/ac011076w</pub-id><pub-id pub-id-type="pmid">11922312</pub-id></citation></ref>
<ref id="b35-ijms-11-00206"><label>35.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Foquet</surname><given-names>M</given-names></name><name><surname>Korlach</surname><given-names>J</given-names></name><name><surname>Zipfel</surname><given-names>WR</given-names></name><name><surname>Webb</surname><given-names>WW</given-names></name><name><surname>Craighead</surname><given-names>HG</given-names></name></person-group><article-title>Focal volume confinement by submicrometer-sized fluidic channels</article-title><source>Anal. Chem</source><year>2004</year><volume>76</volume><fpage>1618</fpage><lpage>1626</lpage><pub-id pub-id-type="doi">10.1021/ac035088o</pub-id><pub-id pub-id-type="pmid">15018559</pub-id></citation></ref>
<ref id="b36-ijms-11-00206"><label>36.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lenne</surname><given-names>PF</given-names></name><name><surname>Colombo</surname><given-names>D</given-names></name><name><surname>Giovannini</surname><given-names>H</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name></person-group><article-title>Flow profiles and directionality in microcapillaries measured by fluorescence correlation spectroscopy</article-title><source>Single Mol</source><year>2002</year><volume>3</volume><fpage>194</fpage><lpage>200</lpage><pub-id pub-id-type="doi">10.1002/1438-5171(200208)3:4&lt;194::AID-SIMO194&gt;3.0.CO;2-0</pub-id></citation></ref>
<ref id="b37-ijms-11-00206"><label>37.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yin</surname><given-names>D</given-names></name><name><surname>Lunt</surname><given-names>EJ</given-names></name><name><surname>Barman</surname><given-names>A</given-names></name><name><surname>Hawkins</surname><given-names>AR</given-names></name><name><surname>Schmidt</surname><given-names>H</given-names></name></person-group><article-title>Microphotonic control of single molecule fluorescence correlation spectroscopy using planar optofluidics</article-title><source>Opt. Express</source><year>2007</year><volume>15</volume><fpage>7290</fpage><lpage>7295</lpage><pub-id pub-id-type="doi">10.1364/OE.15.007290</pub-id><pub-id pub-id-type="pmid">19547052</pub-id></citation></ref>
<ref id="b38-ijms-11-00206"><label>38.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lewis</surname><given-names>A</given-names></name><name><surname>Taha</surname><given-names>H</given-names></name><name><surname>Strinkovski</surname><given-names>A</given-names></name><name><surname>Menevitch</surname><given-names>A</given-names></name><name><surname>Katchatouriants</surname><given-names>A</given-names></name><name><surname>Dekhter</surname><given-names>R</given-names></name><name><surname>Amman</surname><given-names>E</given-names></name></person-group><article-title>Near-field optics: From subwavelength illumination to nanometric shadowing</article-title><source>Nat. Biotechnol</source><year>2003</year><volume>21</volume><fpage>1378</fpage><lpage>1386</lpage><pub-id pub-id-type="doi">10.1038/nbt898</pub-id><pub-id pub-id-type="pmid">14595366</pub-id></citation></ref>
<ref id="b39-ijms-11-00206"><label>39.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vobornik</surname><given-names>D</given-names></name><name><surname>Banks</surname><given-names>DS</given-names></name><name><surname>Lu</surname><given-names>Z</given-names></name><name><surname>Fradin</surname><given-names>C</given-names></name><name><surname>Taylor</surname><given-names>R</given-names></name><name><surname>Johnston</surname><given-names>LJ</given-names></name></person-group><article-title>Fluorescence correlation spectroscopy with sub-diffraction-limited resolution using near-field optical probes</article-title><source>Appl Phys Lett</source><year>2008</year><volume>93</volume><fpage>163904:1</fpage><lpage>163904:3</lpage></citation></ref>
<ref id="b40-ijms-11-00206"><label>40.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lu</surname><given-names>G</given-names></name><name><surname>Lei</surname><given-names>FH</given-names></name><name><surname>Angiboust</surname><given-names>JF</given-names></name><name><surname>Manfait</surname><given-names>M</given-names></name></person-group><article-title>Confined detection volume of fluorescence correlation spectroscopy by bare fiber probes</article-title><source>Eur Biophys J</source><year>2009</year>doi:10.1007/s00249-009-0508-z</citation></ref>
<ref id="b41-ijms-11-00206"><label>41.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Herrmann</surname><given-names>M</given-names></name><name><surname>Neuberth</surname><given-names>N</given-names></name><name><surname>Wissler</surname><given-names>J</given-names></name><name><surname>Pérez</surname><given-names>J</given-names></name><name><surname>Gradl</surname><given-names>D</given-names></name><name><surname>Naber</surname><given-names>A</given-names></name></person-group><article-title>Near-field optical study of protein transport kinetics at a single nuclear pore</article-title><source>Nano Lett</source><year>2009</year><volume>9</volume><fpage>3330</fpage><lpage>3336</lpage><pub-id pub-id-type="doi">10.1021/nl901598z</pub-id><pub-id pub-id-type="pmid">19591452</pub-id></citation></ref>
<ref id="b42-ijms-11-00206"><label>42.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Levene</surname><given-names>MJ</given-names></name><name><surname>Korlach</surname><given-names>J</given-names></name><name><surname>Turner</surname><given-names>SW</given-names></name><name><surname>Foquet</surname><given-names>M</given-names></name><name><surname>Craighead</surname><given-names>HG</given-names></name><name><surname>Webb</surname><given-names>WW</given-names></name></person-group><article-title>Zero-mode waveguides for single-molecule analysis at high concentrations</article-title><source>Science</source><year>2003</year><volume>299</volume><fpage>682</fpage><lpage>686</lpage><pub-id pub-id-type="doi">10.1126/science.1079700</pub-id><pub-id pub-id-type="pmid">12560545</pub-id></citation></ref>
<ref id="b43-ijms-11-00206"><label>43.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Samiee</surname><given-names>KT</given-names></name><name><surname>Foquet</surname><given-names>M</given-names></name><name><surname>Guo</surname><given-names>L</given-names></name><name><surname>Cox</surname><given-names>EC</given-names></name><name><surname>Craighead</surname><given-names>HG</given-names></name></person-group><article-title>Lambda repressor oligomerization kinetics at high concentrations using fluorescence correlation spectroscopy in zero-mode waveguides</article-title><source>Biophys. J</source><year>2005</year><volume>88</volume><fpage>2145</fpage><lpage>2153</lpage><pub-id pub-id-type="doi">10.1529/biophysj.104.052795</pub-id><pub-id pub-id-type="pmid">15613638</pub-id></citation></ref>
<ref id="b44-ijms-11-00206"><label>44.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Leutenegger</surname><given-names>M</given-names></name><name><surname>Gösch</surname><given-names>M</given-names></name><name><surname>Perentes</surname><given-names>A</given-names></name><name><surname>Hoffmann</surname><given-names>P</given-names></name><name><surname>Martin</surname><given-names>OJF</given-names></name><name><surname>Lasser</surname><given-names>T</given-names></name></person-group><article-title>Confining the sampling volume for Fluorescence Correlation Spectroscopy using a sub-wavelength sized aperture</article-title><source>Opt. Express</source><year>2006</year><volume>14</volume><fpage>956</fpage><lpage>969</lpage><pub-id pub-id-type="doi">10.1364/OPEX.14.000956</pub-id><pub-id pub-id-type="pmid">19503416</pub-id></citation></ref>
<ref id="b45-ijms-11-00206"><label>45.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Gérard</surname><given-names>D</given-names></name><name><surname>Lenne</surname><given-names>PF</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Dintinger</surname><given-names>J</given-names></name><name><surname>Ebbesen</surname><given-names>TW</given-names></name><name><surname>Boned</surname><given-names>A</given-names></name><name><surname>Conchonaud</surname><given-names>F</given-names></name><name><surname>Marguet</surname><given-names>D</given-names></name></person-group><article-title>Dual-color fluorescence cross-correlation spectroscopy in a single nanoaperture: Towards rapid multicomponent screening at high concentrations</article-title><source>Opt. Express</source><year>2006</year><volume>14</volume><fpage>12206</fpage><lpage>12216</lpage><pub-id pub-id-type="doi">10.1364/OE.14.012206</pub-id><pub-id pub-id-type="pmid">19529650</pub-id></citation></ref>
<ref id="b46-ijms-11-00206"><label>46.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liao</surname><given-names>D</given-names></name><name><surname>Galajda</surname><given-names>P</given-names></name><name><surname>Riehn</surname><given-names>R</given-names></name><name><surname>Ilic</surname><given-names>R</given-names></name><name><surname>Puchalla</surname><given-names>JL</given-names></name><name><surname>Yu</surname><given-names>HG</given-names></name><name><surname>Craighead</surname><given-names>HG</given-names></name><name><surname>Austin</surname><given-names>RH</given-names></name></person-group><article-title>Single molecule correlation spectroscopy in continuous flow mixers with zero-mode waveguides</article-title><source>Opt. Express</source><year>2008</year><volume>16</volume><fpage>10077</fpage><lpage>10090</lpage><pub-id pub-id-type="doi">10.1364/OE.16.010077</pub-id><pub-id pub-id-type="pmid">18607415</pub-id></citation></ref>
<ref id="b47-ijms-11-00206"><label>47.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Capoulade</surname><given-names>J</given-names></name><name><surname>Dintinger</surname><given-names>J</given-names></name><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Bonod</surname><given-names>N</given-names></name><name><surname>Popov</surname><given-names>E</given-names></name><name><surname>Ebbesen</surname><given-names>TW</given-names></name><name><surname>Lenne</surname><given-names>PF</given-names></name></person-group><article-title>Enhancement of single-molecule fluorescence detection in subwavelength apertures</article-title><source>Phys Rev Lett</source><year>2005</year><volume>95</volume><fpage>117401:1</fpage><lpage>117401:4</lpage></citation></ref>
<ref id="b48-ijms-11-00206"><label>48.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Lenne</surname><given-names>PF</given-names></name><name><surname>Popov</surname><given-names>E</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Dintinger</surname><given-names>J</given-names></name><name><surname>Ebbesen</surname><given-names>TW</given-names></name></person-group><article-title>Single molecule fluorescence in rectangular nano-apertures</article-title><source>Opt. Express</source><year>2005</year><volume>13</volume><fpage>7035</fpage><lpage>7044</lpage><pub-id pub-id-type="doi">10.1364/OPEX.13.007035</pub-id><pub-id pub-id-type="pmid">19498725</pub-id></citation></ref>
<ref id="b49-ijms-11-00206"><label>49.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Gérard</surname><given-names>D</given-names></name><name><surname>Bonod</surname><given-names>N</given-names></name><name><surname>Popov</surname><given-names>E</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Dintinger</surname><given-names>J</given-names></name><name><surname>Mahboub</surname><given-names>O</given-names></name><name><surname>Ebbesen</surname><given-names>TW</given-names></name></person-group><article-title>Emission and excitation contributions to enhanced single molecule fluorescence by gold nanometric apertures</article-title><source>Opt. Express</source><year>2008</year><volume>16</volume><fpage>3008</fpage><lpage>3020</lpage><pub-id pub-id-type="doi">10.1364/OE.16.003008</pub-id><pub-id pub-id-type="pmid">18542387</pub-id></citation></ref>
<ref id="b50-ijms-11-00206"><label>50.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gérard</surname><given-names>D</given-names></name><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Bonod</surname><given-names>N</given-names></name><name><surname>Popov</surname><given-names>E</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Mahdavi</surname><given-names>F</given-names></name><name><surname>Blair</surname><given-names>S</given-names></name><name><surname>Dintinger</surname><given-names>J</given-names></name><name><surname>Ebbesen</surname><given-names>TW</given-names></name></person-group><article-title>Nanoaperture-enhanced fluorescence: Towards higher detection rates with plasmonic metals</article-title><source>Phys Rev B</source><year>2008</year><volume>77</volume><fpage>045413</fpage>doi:10.1103/PhysRevB.77.045413<pub-id pub-id-type="doi">10.1103/PhysRevB.77.045413</pub-id></citation></ref>
<ref id="b51-ijms-11-00206"><label>51.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aouani</surname><given-names>H</given-names></name><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Gérard</surname><given-names>D</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Devaux</surname><given-names>E</given-names></name><name><surname>Ebbesen</surname><given-names>TW</given-names></name><name><surname>Mahdavi</surname><given-names>F</given-names></name><name><surname>Xu</surname><given-names>T</given-names></name><name><surname>Blair</surname><given-names>S</given-names></name></person-group><article-title>Crucial role of the adhesion layer on the plasmonic fluorescence enhancement</article-title><source>ACS Nano</source><year>2009</year><volume>3</volume><fpage>2043</fpage><lpage>2048</lpage><pub-id pub-id-type="doi">10.1021/nn900460t</pub-id><pub-id pub-id-type="pmid">19518085</pub-id></citation></ref>
<ref id="b52-ijms-11-00206"><label>52.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Gérard</surname><given-names>D</given-names></name><name><surname>Aouani</surname><given-names>H</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Lowder</surname><given-names>B</given-names></name><name><surname>Blair</surname><given-names>S</given-names></name><name><surname>Devaux</surname><given-names>E</given-names></name><name><surname>Ebbesen</surname><given-names>TW</given-names></name></person-group><article-title>Nanoaperture-enhanced signal-to-noise ratio in fluorescence correlation spectroscopy</article-title><source>Anal. Chem</source><year>2009</year><volume>81</volume><fpage>834</fpage><lpage>839</lpage><pub-id pub-id-type="doi">10.1021/ac8024015</pub-id><pub-id pub-id-type="pmid">19099408</pub-id></citation></ref>
<ref id="b53-ijms-11-00206"><label>53.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lenne</surname><given-names>PF</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Marguet</surname><given-names>D</given-names></name><name><surname>Wenger</surname><given-names>J</given-names></name></person-group><article-title>Fluorescence fluctuations analysis in nanoapertures: Physical concepts and biological applications</article-title><source>Histochem. Cell Biol</source><year>2008</year><volume>130</volume><fpage>795</fpage><lpage>805</lpage><pub-id pub-id-type="doi">10.1007/s00418-008-0507-7</pub-id><pub-id pub-id-type="pmid">18800223</pub-id></citation></ref>
<ref id="b54-ijms-11-00206"><label>54.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Samiee</surname><given-names>KT</given-names></name><name><surname>Moran-Mirabal</surname><given-names>JM</given-names></name><name><surname>Cheung</surname><given-names>YK</given-names></name><name><surname>Craighead</surname><given-names>HG</given-names></name></person-group><article-title>Zero mode waveguides for single-molecule spectroscopy on lipid membranes</article-title><source>Biophys. J</source><year>2006</year><volume>90</volume><fpage>3288</fpage><lpage>3299</lpage><pub-id pub-id-type="doi">10.1529/biophysj.105.072819</pub-id><pub-id pub-id-type="pmid">16461393</pub-id></citation></ref>
<ref id="b55-ijms-11-00206"><label>55.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Dintinger</surname><given-names>J</given-names></name><name><surname>Marguet</surname><given-names>D</given-names></name><name><surname>Lenne</surname><given-names>PF</given-names></name></person-group><article-title>Single-fluorophore diffusion in a lipid membrane over a subwavelength aperture</article-title><source>J Biol Phys</source><year>2006</year><volume>32</volume><fpage>SN1</fpage><lpage>SN4</lpage><pub-id pub-id-type="doi">10.1007/s10867-006-2909-x</pub-id><pub-id pub-id-type="pmid">19669430</pub-id></citation></ref>
<ref id="b56-ijms-11-00206"><label>56.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Edel</surname><given-names>JB</given-names></name><name><surname>Wu</surname><given-names>M</given-names></name><name><surname>Baird</surname><given-names>B</given-names></name><name><surname>Craighead</surname><given-names>HG</given-names></name></person-group><article-title>High spatial resolution observation of single molecule dynamics in living cell membranes</article-title><source>Biophys. J</source><year>2005</year><volume>88</volume><fpage>L43</fpage><lpage>L45</lpage><pub-id pub-id-type="doi">10.1529/biophysj.105.061937</pub-id><pub-id pub-id-type="pmid">15821167</pub-id></citation></ref>
<ref id="b57-ijms-11-00206"><label>57.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wenger</surname><given-names>J</given-names></name><name><surname>Conchonaud</surname><given-names>F</given-names></name><name><surname>Dintinger</surname><given-names>J</given-names></name><name><surname>Wawrezinieck</surname><given-names>L</given-names></name><name><surname>Ebbesen</surname><given-names>TW</given-names></name><name><surname>Rigneault</surname><given-names>H</given-names></name><name><surname>Marguet</surname><given-names>D</given-names></name><name><surname>Lenne</surname><given-names>PF</given-names></name></person-group><article-title>Diffusion analysis within single nanometric apertures reveals the ultrafine cell membrane organization</article-title><source>Biophys. J</source><year>2007</year><volume>92</volume><fpage>913</fpage><lpage>919</lpage><pub-id pub-id-type="doi">10.1529/biophysj.106.096586</pub-id><pub-id pub-id-type="pmid">17085499</pub-id></citation></ref>
<ref id="b58-ijms-11-00206"><label>58.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Moran-Mirabal</surname><given-names>JM</given-names></name><name><surname>Torres</surname><given-names>AJ</given-names></name><name><surname>Samiee</surname><given-names>KT</given-names></name><name><surname>Baird</surname><given-names>B</given-names></name><name><surname>Craighead</surname><given-names>HG</given-names></name></person-group><article-title>Cell investigation of nanostructures: Zero-mode waveguides for plasma membrane studies with single molecule resolution</article-title><source>Nanotechnology</source><year>2007</year><volume>18</volume><fpage>195101:1</fpage><lpage>195101:10</lpage></citation></ref>
<ref id="b59-ijms-11-00206"><label>59.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Eid</surname><given-names>J</given-names></name><name><surname>Fehr</surname><given-names>A</given-names></name><name><surname>Gray</surname><given-names>J</given-names></name><name><surname>Luong</surname><given-names>K</given-names></name><name><surname>Lyle</surname><given-names>J</given-names></name><name><surname>Otto</surname><given-names>G</given-names></name><name><surname>Peluso</surname><given-names>P</given-names></name><name><surname>Rank</surname><given-names>D</given-names></name><name><surname>Baybayan</surname><given-names>P</given-names></name><name><surname>Bettman</surname><given-names>B</given-names></name><name><surname>Bibillo</surname><given-names>A</given-names></name><name><surname>Bjornson</surname><given-names>K</given-names></name><name><surname>Chaudhuri</surname><given-names>B</given-names></name><name><surname>Christians</surname><given-names>F</given-names></name><name><surname>Cicero</surname><given-names>R</given-names></name><name><surname>Clark</surname><given-names>S</given-names></name><name><surname>Dalal</surname><given-names>R</given-names></name><name><surname>deWinter</surname><given-names>A</given-names></name><name><surname>Dixon</surname><given-names>J</given-names></name><name><surname>Foquet</surname><given-names>M</given-names></name><name><surname>Gaertner</surname><given-names>A</given-names></name><name><surname>Hardenbol</surname><given-names>P</given-names></name><name><surname>Heiner</surname><given-names>C</given-names></name><name><surname>Hester</surname><given-names>K</given-names></name><name><surname>Holden</surname><given-names>D</given-names></name><name><surname>Kearns</surname><given-names>G</given-names></name><name><surname>Kong</surname><given-names>X</given-names></name><name><surname>Kuse</surname><given-names>R</given-names></name><name><surname>Lacroix</surname><given-names>Y</given-names></name><name><surname>Lin</surname><given-names>S</given-names></name><name><surname>Lundquist</surname><given-names>P</given-names></name><name><surname>Ma</surname><given-names>C</given-names></name><name><surname>Marks</surname><given-names>P</given-names></name><name><surname>Maxham</surname><given-names>M</given-names></name><name><surname>Murphy</surname><given-names>D</given-names></name><name><surname>Park</surname><given-names>I</given-names></name><name><surname>Pham</surname><given-names>T</given-names></name><name><surname>Phillips</surname><given-names>M</given-names></name><name><surname>Roy</surname><given-names>J</given-names></name><name><surname>Sebra</surname><given-names>R</given-names></name><name><surname>Shen</surname><given-names>G</given-names></name><name><surname>Sorenson</surname><given-names>J</given-names></name><name><surname>Tomaney</surname><given-names>A</given-names></name><name><surname>Travers</surname><given-names>K</given-names></name><name><surname>Trulson</surname><given-names>M</given-names></name><name><surname>Vieceli</surname><given-names>J</given-names></name><name><surname>Wegener</surname><given-names>J</given-names></name><name><surname>Wu</surname><given-names>D</given-names></name><name><surname>Yang</surname><given-names>A</given-names></name><name><surname>Zaccarin</surname><given-names>D</given-names></name><name><surname>Zhao</surname><given-names>P</given-names></name><name><surname>Zhong</surname><given-names>F</given-names></name><name><surname>Korlach</surname><given-names>J</given-names></name><name><surname>Turner</surname><given-names>S</given-names></name></person-group><article-title>Real-time DNA sequencing from single polymerase molecules</article-title><source>Science</source><year>2009</year><volume>323</volume><fpage>133</fpage><lpage>138</lpage><pub-id pub-id-type="doi">10.1126/science.1162986</pub-id><pub-id pub-id-type="pmid">19023044</pub-id></citation></ref></ref-list>
<sec sec-type="display-objects">
<title>Figures and Table</title>
<fig id="f1-ijms-11-00206" position="float">
<label>Figure 1.</label>
<caption>
<p>State-of-the-art for single molecule detection in solution based on a confocal microscope and fluorescence correlation analysis. The inset shows the size of the typical analysis volume.</p></caption><graphic xlink:href="ijms-11-00206f1.gif"/></fig>
<fig id="f2-ijms-11-00206" position="float">
<label>Figure 2.</label>
<caption>
<p>As in computer engineering, nanosciences enable major breakthroughs in designing novel microscope tools and devices (computers pictures courtesy of Wikipedia.org).</p></caption><graphic xlink:href="ijms-11-00206f2.gif"/></fig>
<fig id="f3-ijms-11-00206" position="float">
<label>Figure 3.</label>
<caption>
<p>Designs for improved single molecule fluorescence detection by structuring the laser excitation beam; see text for details.</p></caption><graphic xlink:href="ijms-11-00206f3.gif"/></fig>
<fig id="f4-ijms-11-00206" position="float">
<label>Figure 4.</label>
<caption>
<p>Designs for improved single molecule fluorescence detection by using photonic structures; see text for details.</p></caption><graphic xlink:href="ijms-11-00206f4.gif"/></fig>
<fig id="f5-ijms-11-00206" position="float">
<label>Figure 5.</label>
<caption>
<p>Range for analysis volumes and corresponding concentrations to ensure one single molecule in the analysis volume for the different schemes discussed here.</p></caption><graphic xlink:href="ijms-11-00206f5.gif"/></fig>
<table-wrap id="t1-ijms-11-00206" position="float">
<label>Table 1.</label>
<caption>
<p>Summary of the two main characteristics for single molecule detection systems: volume reduction and fluorescence signal enhancement factors as compared to state-of-the-art confocal microscope.</p></caption>
<table frame="box" rules="cols">
<thead>
<tr>
<th valign="bottom" align="center">Type</th>
<th valign="bottom" align="center">Volume reduction</th>
<th valign="bottom" align="center">Fluo. enhancement</th>
<th valign="bottom" align="center">Complexity</th></tr></thead>
<tbody>
<tr>
<td valign="top" align="left" colspan="4"><hr/></td></tr>
<tr>
<td valign="top" align="center">Confocal</td>
<td valign="top" align="center">x1</td>
<td valign="top" align="center">x1</td>
<td valign="top" align="center">*</td></tr>
<tr>
<td valign="top" align="left" colspan="4"><hr/></td></tr>
<tr>
<td valign="top" align="center">TIRF</td>
<td valign="top" align="center">x10</td>
<td valign="top" align="center">x2</td>
<td valign="top" align="center">*</td></tr>
<tr>
<td valign="top" align="center">Mirror</td>
<td valign="top" align="center">x6</td>
<td valign="top" align="center">x4</td>
<td valign="top" align="center">*</td></tr>
<tr>
<td valign="top" align="center">4Pi</td>
<td valign="top" align="center">x6</td>
<td valign="top" align="center">x4</td>
<td valign="top" align="center">***</td></tr>
<tr>
<td valign="top" align="center">STED</td>
<td valign="top" align="center">x100</td>
<td valign="top" align="center">?</td>
<td valign="top" align="center">***</td></tr>
<tr>
<td valign="top" align="left" colspan="4"><hr/></td></tr>
<tr>
<td valign="top" align="center">Paraboloid</td>
<td valign="top" align="center">x10</td>
<td valign="top" align="center">x2</td>
<td valign="top" align="center">*</td></tr>
<tr>
<td valign="top" align="center">SIL</td>
<td valign="top" align="center">x3</td>
<td valign="top" align="center">x1.5</td>
<td valign="top" align="center">**</td></tr>
<tr>
<td valign="top" align="center">Microsphere</td>
<td valign="top" align="center">x10</td>
<td valign="top" align="center">x5</td>
<td valign="top" align="center">*</td></tr>
<tr>
<td valign="top" align="center">Nanofluidics</td>
<td valign="top" align="center">x100</td>
<td valign="top" align="center">x3</td>
<td valign="top" align="center">**</td></tr>
<tr>
<td valign="top" align="center">NSOM</td>
<td valign="top" align="center">x100</td>
<td valign="top" align="center">?</td>
<td valign="top" align="center">***</td></tr>
<tr>
<td valign="top" align="center">Nanoapertures</td>
<td valign="top" align="center">x1000</td>
<td valign="top" align="center">x25</td>
<td valign="top" align="center">**</td></tr></tbody></table></table-wrap></sec></back></article>
