Medicina is published by MDPI from Volume 54 Issue 1 (2018). Articles in this Issue were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence. Articles are hosted by MDPI on mdpi.com as a courtesy and upon agreement with Lithuanian Medical Association, Lithuanian University of Health Sciences, and Vilnius University.
Open AccessArticle
Medicina 2017, 53(4), 242-252; https://doi.org/10.1016/j.medici.2017.05.007 (registering DOI)

Morphometric parameters of the optic disc in normal and glaucomatous eyes based on time-domain optical coherence tomography image analysis

1
Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
2
Laboratory of Biophysics and Bioinformatics, Neuroscience Institute, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
Deceased.
*
Author to whom correspondence should be addressed.
Received: 2 October 2015 / Revised: 23 April 2017 / Accepted: 23 May 2017 / Published: 18 July 2017
Download PDF [1389 KB, uploaded 25 February 2018]

Abstract

Background and objective: Assessment of optic disc morphology is essential in diagnosis and management of visual impairment. The aim of this study was to evaluate associations between optic disc morphometric parameters, i.e., size and shape, and age, gender, and ocular axial length in normal and glaucomatous eyes based on time-domain optical coherence tomography image analysis.
Materials and methods: It was a case–control study of 998 normal and 394 eyes with primary open angle glaucoma that underwent an ophthalmological examination and time-domain optical coherence topography scanning. Areas and shapes of the disc, cup, and neuroretinal rim were analyzed.
Results: The shape of the optic disc did not differ between the study groups, i.e., normal and glaucomatous case groups, but the disc area of the primary open angle glaucoma group was significantly larger. The shape of the small disc was significantly different, but the shape of the medium and the large disc did not differ between the study groups. The central area of the disc, i.e., cup area was significantly larger in the case group and its shape was significantly different between the study groups. No significant differences in the area of the cup and its shape, nerve fibers on the edge of the disc, i.e., neuroretinal rim area, were found between the study groups of the small discs. There were significant associations between age, gender, and ocular axial length and morphometric parameters of the optic disc.
Conclusions: Informative results with regard to the size and shape due to various ocular characteristics between the healthy control group and patients suffering with primary open angle glaucoma were obtained. Both study groups were significant in size, which makes the findings interesting and important contribution in the field.
Keywords: Retina Optic disc; Neuroretinal rim; Primary open angle glaucoma; Time-domain optical coherence tomography Retina Optic disc; Neuroretinal rim; Primary open angle glaucoma; Time-domain optical coherence tomography
This is an open access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives License (CC BY-NC-ND) (CC BY-NC-ND).

Share & Cite This Article

MDPI and ACS Style

Buteikienė, D.; Kybartaitė-Žilienė, A.; Kriaučiūnienė, L.; Barzdžiukas, V.; Janulevičienė, I.; Paunksnis, A. Morphometric parameters of the optic disc in normal and glaucomatous eyes based on time-domain optical coherence tomography image analysis. Medicina 2017, 53, 242-252.

Show more citation formats Show less citations formats

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Medicina EISSN 1010-660X Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top